Installation Instructions _________

Installation should be performed by qualified professional in 

accordance with local, state, and country codes. In the absence 

of these codes, the installation must conform to applicable 

American National Standards: ANSI Z223.1- LATEST EDITION 

(National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST 

EDITION (National Electrical Code) or in Canada, the installation 

must conform to applicable Canadian Standards: CAN/CGA-

B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91  

(Propane Gas) or LATEST EDITION (for General Installation and 

Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA 

C22.1-1990 or LATEST EDITION (for Electrical Connections).

Tools Required

 

ʍ

Utility Knife to remove packaging

 

ʍ

9/16" Box wrench or 9/16" socket to remove pallet bolts

 

ʍ

#2 Phillips screwdriver to open box cover

 

ʍ

Pipe wrench for gas connections

 

ʍ

7/8" open end wrench or adjustable wrench to install 

coin box lock

Leveling feet adjustment

 

ʍ

TORX

®†

 T20 TORX

®

 T25 to open front and rear to get foot 

adjustment ends

 

ʍ

1/4" socket or 1/4" open end wrench to make the 

adjustment

Moving to Final Location

1. 

Move the dryer near the point of installation.

2. 

Use a carton knife to cut the plastic film.

3. 

Remove all plastic wrap and corrugated cardboard.

4. 

Dispose of/recycle all packaging material.

Leveling Dryer

The dryer is equipped with 4 leveling legs, 1 at each corner of  

the base. For optimum performance the dryer should be level 

front-to-back and side-to-side.

Location Requirements _________

IMPORTANT:

 The dryer must be installed on noncombustible 

floor only.
The dryer is for use in noncombustible locations.
Before installing the dryer, be sure the location conforms to 

local codes and ordinances. In the absence of such codes or 

ordinances the location must conform with the National Fuel 

Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada, the 

installation must conform to applicable Canadian Standards: 

CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 

(Propane Gas) or LATEST EDITION (for General Installation and 

Gas Plumbing).
The operation of this dryer may affect the operation of other 

types of gas dryers, which take their air for safe combustion from 

the same room. If in doubt, consult the dryer manufacturer(s).
The dryer must be installed on a sound level floor capable of 

supporting its weight. Carpeting must be removed from the floor 

area that the dryer is to rest on.
The dryer must not be installed or stored in an area where it will 

be exposed to water and/or weather.
Provisions for adequate air supply must be provided as noted in 

this manual (refer to Fresh Air Supply Requirements section).
Clearance provisions must be made from combustible 

construction as noted in this manual (refer to Dryer Enclosure 

Requirements section).
Provisions must be made for adequate clearances for servicing 

and for operation as noted in this manual (refer to Dryer 

Enclosure Requirements section).
The dryer must be installed with a proper exhaust duct 

connection to the outside as noted in this manual (refer to 

Exhaust Requirements section).
The dryer must be located in an area where correct exhaust 

venting can be achieved as noted in this manual (refer to Exhaust 

Requirements section).

IMPORTANT:

 The dryer should be located where a minimum 

amount of exhaust ducting will be necessary.
The dryer must be installed with adequate clearance for air 

openings into the combustion chamber.

IMPORTANT:

 The dryer must be installed in a location/ 

environment, which the ambient temperature remains between 

40°F (4.44°C) and 130°F (54.44°C).

WARNING

Excessive Weight Hazard

Use two or more people and mechanical equipment to 

lift, move and install dryer.
Failure to do so can result in back or other injury.

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as 

gasoline, away from dryer.
Failure to do so can result in death, explosion, or fire.

®

Torx and T20 are registered trademarks of Acument Intellectual Properties, LLC.

Содержание MLG30

Страница 1: ...MLG30 Installation Manual Stack Dryer WFR113543E RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Страница 2: ...N HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or...

Страница 3: ..._ HVAC Heating Ventilating and Air Conditioning in WC Inches of Water Column UL Underwriters Laboratory NPT National Pipe Thread Table Of Contents ______________ Caution Label all wires prior to disco...

Страница 4: ...kg APPROXIMATE SHIPPING WEIGHT 710 lb 322 kg AIRFLOW PER POCKET 400 cfm 11 3 cmm HEAT INPUT PER POCKET 72000 Btu hr 18143 kcal hr EXHAUST CONNECTION DIAMETER 8 20 3 cm INLET PIPE CONNECTION PER POCKE...

Страница 5: ...nform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 Propane Gas or LATEST EDITION for General Installation and Gas Plumbing The operation of this dryer may affe...

Страница 6: ...r 1 000 Btu 252 kcal It is not necessary to have a separate make up air opening for each dryer Common make up air openings are acceptable However they must be set up in such a manner that the make up...

Страница 7: ...elbows used exceeds the above noted specifications the cross sectional area of the ductwork may need to be increased IMPORTANT For extended ductwork runs the cross section area of the ductwork can onl...

Страница 8: ...RICAL SERVICE SPECIFICATIONS PER POCKET NOTES A When fuses are used they must be dual element time delay current limiting class RK1 or RK5 ONLY Calculate determine correct fuse value by applying eithe...

Страница 9: ...onnection wiring must be sized properly to handle the dryer s current draw This information is printed on the dryer s data label Fire Hazard Use appropriate gauge of copper wire See chart in Electrica...

Страница 10: ...country of destination and if in doubt the installer must contact the supplier The manufacturer of this dryer does not recommend the use of flexible gas supply line hose Pipe joint compounds that res...

Страница 11: ...immediately upstream of the dryer Test all connections for leaks by brushing on a soapy water solution liquid detergent works well 3 4 x 1 2 x 1 2 TEE 19 05 mm x 12 7 mm x 12 7 mm SEE IMPORTANT NOTE...

Страница 12: ...ry adjustments have been made the dryer must be operated in a heating cycle to verify that the pressure is correct 6 Feed manometer hose through an opening in the back panel while reattaching the back...

Страница 13: ...uctions __________ The dryer is available for use when the appropriate side of the microprocessor display reads 0 minutes and the amount needed to start the dryer i e 25 Once the load has been put int...

Страница 14: ...y lint buildup Suggested Cleaning Schedule Every Third or Fourth Load Clean the lint screen every third or fourth load A clogged lint screen will cause poor dryer performance The lint door drawer is l...

Страница 15: ...Gives the number drill size used 6 Electric Service This describes the voltage and current rating for a particular model 7 Gas Manifold Pressure For Gas Dryers This describes the manifold pressure ta...

Страница 16: ...MLG30 Manuel d installation S cheuse superpos e CONSERVER CES INSTRUCTIONS POUR R F RENCE ULT RIEURE...

Страница 17: ...ce ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas tou...

Страница 18: ...on et Climatisation po CE Pouces de colonne d eau UL Underwriters Laboratory NPT National Pipe Thread Attention Lors des contr les d entretien placer des tiquettes sur l ensemble des c bles avant leur...

Страница 19: ...UEMENT APPROXIMATIF 710 lb 322 kg D BIT D AIR PAR S CHEUSE 400 pi min 11 3 m3 min ENTR E DE CHALEUR PAR S CHEUSE 72 000 Btu h 18 143 kcal h RACCORD D VACUATION DIAM TRE 8 po 20 3 cm RACCORD D ENTR E D...

Страница 20: ...z naturel ou CAN CGA B149 2 M91 gaz propane ou la DERNI RE DITION pour l installation g n rale et la plomberie au gaz L utilisation de cette s cheuse peut affecter celle d autres s cheuses gaz dont la...

Страница 21: ...uverture d air d appoint distincte pour chaque s cheuse Les ouvertures communes pour l air d appoint sont acceptables Toutefois elles doivent tre install es de sorte que l air d appoint est distribu u...

Страница 22: ...onduit IMPORTANT Pour les conduits de longueur prolong e l aire de la section transversale du conduit ne peut tre augment e que dans une certaine mesure Lorsque le nombre de conduits approche les limi...

Страница 23: ...fusibles sont utilis s ils doivent comporter deux l ments tre temporis s de type limiteur de courant classe RK1 ou RK5 UNIQUEMENT Calculez d terminez la bonne valeur de fusible conforme aux codes lec...

Страница 24: ...du circuit de 120 V 15 A au conducteurs restants s cheuse inf rieure comme d crit dans l illustration suivante noir noir blanc blanc et vert au fil de terre du ch ssis Serrer les vis du r ducteur de t...

Страница 25: ...heuse l usine Le r glage ou la conversion des s cheuses sur le terrain pour des altitudes sup rieures 2 000 pi 610 m est effectu en changeant chaque orifice du br leur Si cette conversion est n cessai...

Страница 26: ...les raccordements pour la pr sence des fuites en appliquant une solution d eau savonneuse le d tergent liquide fonctionne bien RACCORD EN T DE 3 4 po x 1 2 po x 1 2 po 19 05 mm x 12 7 mm x 12 7 mm VO...

Страница 27: ...ns le sens antihoraire pour abaisser la pression REMARQUE La pression de sortie est mesur e pendant que le br leur est en marche pour toutes les conditions de r glage du br leur Par cons quent une foi...

Страница 28: ...fi s en cours de route ou en raison de conditions d emplacement marginales installation Mettre sous tension la s cheuse Voir les instructions d installation pour mettre la s cheuse en marche Ouvrir to...

Страница 29: ..._________________ R paration La r paration doit tre effectu e par un technicien ou une entreprise de r paration ayant les qualifications requises ou par le fournisseur de gaz Si une r paration est n c...

Страница 30: ...VEC DES ELEVATIONS ENTRE 610 A 1372M Assembled in Assemble aux USA Whirlpool Corporation TEL 269 923 3000 88 Currant Road FAX 508 678 9447 Fall River MA 02720 4781 mdl service whirlpool com WWW WHIRLP...

Страница 31: ...31...

Страница 32: ...WFR113543E 03 20 TM 2020 Maytag All rights reserved Tous droits r serv s...

Отзывы: