The ductwork should be laid out in such a way that the 

ductwork travels as directly as possible to the outdoors with 

as few turns as possible. Single or independent dryer venting 

is recommended. It is suggested that the use of 90° turns be 

avoided; use 30° and/or 45° bends instead. The radius of the 

elbows should preferably be 1-1/2 times the diameter of the 

duct. All ductwork should be smooth inside with no projections 

from sheet metal screws or other obstructions, which will collect 

lint. When adding ducts, overlap the duct being connected. 

All ductwork joints must be taped to prevent moisture and lint 

from escaping into the building. Inspection doors should be 

installed at strategic points in the exhaust ductwork for periodic 

inspection and cleaning of lint from the ductwork.

IMPORTANT:

 Exhaust back pressure measured by a 

manometer/magnehelic in the exhaust duct must be no less 

than 0 and must not exceed 0.3 in WC (0.75 mb).

NOTE:

 It is recommended that exhaust or booster fans not be 

used in the exhaust ductwork system except where necessary 

to maintain exhaust back pressure (in the exhaust duct) between 

zero and 0.3" water column. Where employed, booster fans 

must not activate the dryer airflow proving switch (sail switch) 

when the dryer is not in operation.

NOTE:

 When the exhaust ductwork passes through a wall, 

ceiling, or roof made of combustible materials, the opening must 

be 2" (5.08 cm) larger than the duct (all the way around). The 

duct must be centered within this opening.
The ductwork for this dryer must be suitable for the appliance 

category in accordance with national installation regulations of 

the country of destination.

Outside Ductwork Protection

To protect the outside end of the horizontal ductwork from the 

weather, a 90° elbow bent downward should be installed where 

the exhaust exits the building. If the ductwork travels vertically 

up through the roof, it should be protected from the weather by 

using a 180° turn to point the opening downward. In either case, 

allow at least twice the diameter of the duct between the duct 

opening and the nearest obstruction (refer to the diagram).

IMPORTANT:

 Do not use screens, louvers, or caps on the 

outside opening of the exhaust ductwork.

Single Dryer Venting (8

"

 Duct)

IMPORTANT:

 A minimum exhaust duct size of 8" (20.3 cm) 

must be used.
For an 8" (20.3 cm) run where a maximum of two elbows are 

used (refer to the illustration below), the ductwork from the dryer 

outlet must not exceed 10' (3.0 m).
This calculation of 10' (3.0 m) compensates or allows for the use 

of a maximum of two elbows. Refer to the illustration below.

If the length of the duct run or quantity of elbows used exceeds 

the above noted specifications, the cross-sectional area of the 

ductwork may need to be increased.

IMPORTANT:

 For extended ductwork runs, the cross section 

area of the ductwork can only be increased to an extent. When 

the ductwork approaches the maximum limits noted in this 

manual, a professional HVAC firm should be consulted for 

proper venting information.

Single Dryer Venting (10

"

 Duct)

IMPORTANT:

 A minimum exhaust duct size of 10" (25.4 cm) 

must be used for extended runs.
For a 10" (25.4 cm) run where a maximum of two elbows are 

used (refer to the illustration below), the ductwork from the dryer 

outlet must not exceed 45' (13.7 m).
This calculation of 45' (13.7 m) compensates or allows for the 

use of a maximum of two elbows. Refer to the illustration below.

If the length of the duct run or quantity of elbows used exceeds 

the above noted specifications, the cross-sectional area of the 

ductwork may need to be increased.

IMPORTANT:

 For extended ductwork runs, the cross section 

area of the ductwork can only be increased to an extent. When 

the ductwork approaches the maximum limits noted in this 

manual, a professional HVAC firm should be consulted for 

proper venting information.

Multiple Dryer (Common) Venting

If it is not feasible to provide separate exhaust ducts for each 

dryer, ducts from individual dryers may be channeled into a 

“common main duct.” The individual ducts should enter the 

bottom or side of the main duct at an angle not more than 45° in 

the direction of airflow. The main duct should be tapered, with 

the diameter increasing before each individual 10" (25.4 cm) 

duct (when dryer common exhaust is used) is added.

IMPORTANT:

 No more than four dryers or eight tumblers total 

should be connected to one main common duct.
The main duct may be any shape provided that the minimum 

cross-sectional area is maintained. The illustration below shows 

the minimum cross-sectional area for multiple dryer venting. 

These figures must be increased if the main duct run from the 

last dryer to where it exhausts to the outdoors is unusually long 

(over 30' [9.1 m]) or has numerous elbows (more than one) in it.

SINGLE DRYER VENTING

SINGLE DRYER VENTING (10

"

 DUCT)

2 x D CLEARANCE

8

"

 (20.32 cm) RND DUCT

10 FEET 

MAXIMUM  

(3.05 m)

NOTE A ROOF

INSPECTION 

DOOR

NOTE A  OPENING MUST BE 2

"

(5.08 cm) LARGER THAN THE DUCT (ALL THE    

WAY AROUND). THE DUCT MUST BE CENTERED WITHIN THIS OPENING

VERTICAL

HORIZONTAL

10 FEET MAXIMUM (3.05 m)

INSPECTION 

 DOOR

NOTE A

8

"

 (20.32 cm) 

RND DUCT

2 x D CLEARANCE

2 x D CLEARANCE

VERTICAL

HORIZONTAL

INSPECTION 

DOOR

8

"

(20.3 cm)

DRYER 

CONNECTION

8

"

(20.3 cm)

DRYER 

CONNECTION

INSPECTION 

DOOR

10

"

(25.4 cm) 

DUCT

45 FT MAX 

(13.7 m) 

45 FT  

MAX 

(13.7 m)

10

"

(25.4 cm) RND DUCT

NOTE A  OPENING MUST BE 2

"

(5.08 cm) LARGER THAN THE DUCT (ALL THE    

WAY AROUND). THE DUCT MUST BE CENTERED WITHIN THIS OPENING

NOTE A

NOTE A

ROOF

2 x D CLEARANCE

Содержание MLG30

Страница 1: ...MLG30 Installation Manual Stack Dryer WFR113543E RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Страница 2: ...N HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or...

Страница 3: ..._ HVAC Heating Ventilating and Air Conditioning in WC Inches of Water Column UL Underwriters Laboratory NPT National Pipe Thread Table Of Contents ______________ Caution Label all wires prior to disco...

Страница 4: ...kg APPROXIMATE SHIPPING WEIGHT 710 lb 322 kg AIRFLOW PER POCKET 400 cfm 11 3 cmm HEAT INPUT PER POCKET 72000 Btu hr 18143 kcal hr EXHAUST CONNECTION DIAMETER 8 20 3 cm INLET PIPE CONNECTION PER POCKE...

Страница 5: ...nform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 Propane Gas or LATEST EDITION for General Installation and Gas Plumbing The operation of this dryer may affe...

Страница 6: ...r 1 000 Btu 252 kcal It is not necessary to have a separate make up air opening for each dryer Common make up air openings are acceptable However they must be set up in such a manner that the make up...

Страница 7: ...elbows used exceeds the above noted specifications the cross sectional area of the ductwork may need to be increased IMPORTANT For extended ductwork runs the cross section area of the ductwork can onl...

Страница 8: ...RICAL SERVICE SPECIFICATIONS PER POCKET NOTES A When fuses are used they must be dual element time delay current limiting class RK1 or RK5 ONLY Calculate determine correct fuse value by applying eithe...

Страница 9: ...onnection wiring must be sized properly to handle the dryer s current draw This information is printed on the dryer s data label Fire Hazard Use appropriate gauge of copper wire See chart in Electrica...

Страница 10: ...country of destination and if in doubt the installer must contact the supplier The manufacturer of this dryer does not recommend the use of flexible gas supply line hose Pipe joint compounds that res...

Страница 11: ...immediately upstream of the dryer Test all connections for leaks by brushing on a soapy water solution liquid detergent works well 3 4 x 1 2 x 1 2 TEE 19 05 mm x 12 7 mm x 12 7 mm SEE IMPORTANT NOTE...

Страница 12: ...ry adjustments have been made the dryer must be operated in a heating cycle to verify that the pressure is correct 6 Feed manometer hose through an opening in the back panel while reattaching the back...

Страница 13: ...uctions __________ The dryer is available for use when the appropriate side of the microprocessor display reads 0 minutes and the amount needed to start the dryer i e 25 Once the load has been put int...

Страница 14: ...y lint buildup Suggested Cleaning Schedule Every Third or Fourth Load Clean the lint screen every third or fourth load A clogged lint screen will cause poor dryer performance The lint door drawer is l...

Страница 15: ...Gives the number drill size used 6 Electric Service This describes the voltage and current rating for a particular model 7 Gas Manifold Pressure For Gas Dryers This describes the manifold pressure ta...

Страница 16: ...MLG30 Manuel d installation S cheuse superpos e CONSERVER CES INSTRUCTIONS POUR R F RENCE ULT RIEURE...

Страница 17: ...ce ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas tou...

Страница 18: ...on et Climatisation po CE Pouces de colonne d eau UL Underwriters Laboratory NPT National Pipe Thread Attention Lors des contr les d entretien placer des tiquettes sur l ensemble des c bles avant leur...

Страница 19: ...UEMENT APPROXIMATIF 710 lb 322 kg D BIT D AIR PAR S CHEUSE 400 pi min 11 3 m3 min ENTR E DE CHALEUR PAR S CHEUSE 72 000 Btu h 18 143 kcal h RACCORD D VACUATION DIAM TRE 8 po 20 3 cm RACCORD D ENTR E D...

Страница 20: ...z naturel ou CAN CGA B149 2 M91 gaz propane ou la DERNI RE DITION pour l installation g n rale et la plomberie au gaz L utilisation de cette s cheuse peut affecter celle d autres s cheuses gaz dont la...

Страница 21: ...uverture d air d appoint distincte pour chaque s cheuse Les ouvertures communes pour l air d appoint sont acceptables Toutefois elles doivent tre install es de sorte que l air d appoint est distribu u...

Страница 22: ...onduit IMPORTANT Pour les conduits de longueur prolong e l aire de la section transversale du conduit ne peut tre augment e que dans une certaine mesure Lorsque le nombre de conduits approche les limi...

Страница 23: ...fusibles sont utilis s ils doivent comporter deux l ments tre temporis s de type limiteur de courant classe RK1 ou RK5 UNIQUEMENT Calculez d terminez la bonne valeur de fusible conforme aux codes lec...

Страница 24: ...du circuit de 120 V 15 A au conducteurs restants s cheuse inf rieure comme d crit dans l illustration suivante noir noir blanc blanc et vert au fil de terre du ch ssis Serrer les vis du r ducteur de t...

Страница 25: ...heuse l usine Le r glage ou la conversion des s cheuses sur le terrain pour des altitudes sup rieures 2 000 pi 610 m est effectu en changeant chaque orifice du br leur Si cette conversion est n cessai...

Страница 26: ...les raccordements pour la pr sence des fuites en appliquant une solution d eau savonneuse le d tergent liquide fonctionne bien RACCORD EN T DE 3 4 po x 1 2 po x 1 2 po 19 05 mm x 12 7 mm x 12 7 mm VO...

Страница 27: ...ns le sens antihoraire pour abaisser la pression REMARQUE La pression de sortie est mesur e pendant que le br leur est en marche pour toutes les conditions de r glage du br leur Par cons quent une foi...

Страница 28: ...fi s en cours de route ou en raison de conditions d emplacement marginales installation Mettre sous tension la s cheuse Voir les instructions d installation pour mettre la s cheuse en marche Ouvrir to...

Страница 29: ..._________________ R paration La r paration doit tre effectu e par un technicien ou une entreprise de r paration ayant les qualifications requises ou par le fournisseur de gaz Si une r paration est n c...

Страница 30: ...VEC DES ELEVATIONS ENTRE 610 A 1372M Assembled in Assemble aux USA Whirlpool Corporation TEL 269 923 3000 88 Currant Road FAX 508 678 9447 Fall River MA 02720 4781 mdl service whirlpool com WWW WHIRLP...

Страница 31: ...31...

Страница 32: ...WFR113543E 03 20 TM 2020 Maytag All rights reserved Tous droits r serv s...

Отзывы: