36
7-Segment Display
SCREEN 0 (Display FAULT CODE)
Setting
No.
Contents
Notes
1
Fault code (present)
SCREEN 1 (Display FAULT CODES)
Setting
No.
Contents
Notes
1
Fault code (latest)
Latest
2
Fault code (2nd)
2nd
3
Fault code (3rd)
3rd
4
Fault code (4th)
4th
5
Fault code (5th)
5th
6
Fault code (6th)
6th
SCREEN 2 (MONITOR MODE)
Setting
No.
Contents
Notes
1
Compressor operation time
unit
:
hr (Multiply by 200,)
2
Operation code
0: Stop
1: Cooling Start-up
2: Heating Start-up
3: Oil Return Operation
4: Heating Operation
5: Defrost Operation
6: Cooling Operation
3
Compressor Reduction Mode
0:OFF,1:ON
4
% demand
unit
:
%
(Cut off the decimal first place.)
5
act % demand
unit
:
%
(Cut off the decimal first place.)
6
Requested ID CFM
unit
:
CFM (Multiply by 10)
7
Reported ID CFM
unit
:
CFM (Multiply by 10)
8
Outdoor FAN RPM
unit
:
RPM (Multiply by 10)
9
Ta (Outdoor Air Temperature)
unit
:
F
10
Td (Discharge Temperature)
unit
:
F
11
Tm (Outdoor Coil Temperature)
unit
:
F
12
Tb (Defrost Sensor Temperature)
unit
:
F
13
Tl (Liquid Temperature)
unit
:
F
14
Pressure Sensor
unit
:
PSI
Содержание Amana VZC20
Страница 6: ...6...
Страница 48: ...48 4 Select YES to continue 5 Select HEAT PUMP 6 Select SYS SETUP...
Страница 55: ...55 NOTE BOOST MODE is applicable only for AVZC200 AB and GVZC20 AA or later revision...
Страница 56: ...56 https partnerlinkmarketing goodmanmfg com goodman info finder plus...
Страница 57: ...57 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 58: ...58 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 59: ...59 THIS PAGE IS INTENTIONALLY LEFT BLANK...