PLATFORM BEGINS TO LOWER ON LH SIDE,
BUT WILL NOT LOWER ON RH SIDE - Continued
5.
Disconnect green wire from the
“S1”
(lowering) solenoid valve
(FIG. 56-1)
. Do
resistance checks on the lock valve wir-
ing harness as follows.
• Connect ohmmeter
(+)
and
(-)
leads to the black wire and contact 1
on the wiring harness connector
(FIG. 56-2)
. Reading should be 0.5
ohm or less.
• Connect ohmmeter
(+)
and
(-)
leads
to the white ground wire and con
tact 2 on the wiring harness connect-
or
(FIG. 56-2)
. Reading should be
0.5 ohm or less.
• If any readings are more than
0.5 ohm, check lock valve wiring
harness for crimps or damage. Repair
wiring harness if possible, or replace
the entire lock valve assembly, if nec-
essary.
DISCONNECTING LOCK VALVE WIRING
FROM LOWERING SOLENOID VALVE
(POWER DOWN POWER UNIT SHOWN)
FIG. 56-1
NOTE:
Ensure ground bolt and
ground wiring connections
on the pump are clean and
tight
(FIG. 56-1)
.
MEASURING RESISTANCE ON LOCK
VALVE WIRING HARNESS
FIG. 56-2
1
2
WIRING
HARNESS
CONNECTOR
WHITE WIRE (-)
(GROUND)
RING TERMINAL
TO “S2” VALVE
BLACK WIRE (+)
6.
Before completing this procedure,
ensure lock valve wiring is recon-
nected to
“S1”
(lowering) solenoid
valve, ground bolt, control switch
wire, and lock valve coil.
VALVE “S1”
LOWERING
SOLENOID VALVE
GREEN
WIRE
LOCK VALVE
WIRING HARNESS
(REF)
GREEN
WIRE
Содержание MXT-25
Страница 1: ...M 20 11 REV A DECEMBER 2020 2020 MAXON Lift Corp...
Страница 2: ......
Страница 7: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 21: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 27: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 27 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 41: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 41 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 61: ......