FLOW CONTROL
VALVE
To prevent damage to fl ow control valve, do not
disassemble the valve.
CAUTION
REMOVING FLOW CONTROL VALVE
(POWER DOWN POWER UNIT)
FIG. 50-2
PLATFORM RAISES SLOWLY - Continued
3.
Remove
fl
ow control valve
(FIGS. 50-1, 50-1A, 50-2 and
50-2A)
. Ensure the
fl
ow control valve operates with a smooth
spring-loaded action. Check for debris inside the valve. Clean
or replace the
fl
ow control valve, if necessary. Reinstall
fl
ow
control valve (if good) or install a replacement.
Torque fl ow
control valve to 30 lb-ft
.
PORT “C1”
FLOW CONTROL
VALVE
REMOVING FLOW CONTROL VALVE
(GRAVITY DOWN POWER UNIT)
FIG. 50-1
PORT “C1”
FIG. 50-1A
FIG. 50-2A