PLATFORM RAISES SLOWLY
POWER DOWN UNIT SHOWN
FIG. 49-1
2.
Check the hydraulic cylinder. With the platform at ve-
hicle
fl
oor level, remove the hydraulic line from the
LOWER
port on the cylinder
(FIG. 49-2)
. Hold the
control switch in the
UP
position for two seconds while
you watch for hydraulic
fl
uid at the
LOWER
port. A few
drops of hydraulic
fl
uid escaping the port is normal.
However, if
fl
uid streams out, piston seals are worn.
Replace cylinder.
1.
Connect voltmeter between solenoid switch terminal
“B”
and ground
(-)
wires connection on pump
(FIG.
49-1)
. Verify that there is a minimum of 12.6 volts DC,
or 24.8 volts DC for 24 volt system, at
“B
.
”
Recharge
the battery if voltmeter indicates less than 12.6 volts
DC, or 25.2 volts DC for 24 volt system.
FIG. 49-2
LOWER PORT
RAISE PORT
GROUND (-) WIRES
CONNECTION
NOTE:
In most cases, you can avoid having to
manually bleed hydraulic system by
correctly positioning Liftgate platform before
disconnecting any lifting cylinder high pres-
sure hydraulic lines.
Keep dirt, water and other contaminants from
entering the hydraulic system. Before open-
ing the hydraulic fl uid reservoir fi ller cap, drain
plug and hydraulic lines, clean up contami-
nants that can get in the openings. Also, pro-
tect the openings from accidental contamina-
tion during maintenance.
CAUTION
TERMINAL “B”
BATTERY (+)
Содержание MXT-25
Страница 1: ...M 20 11 REV A DECEMBER 2020 2020 MAXON Lift Corp...
Страница 2: ......
Страница 7: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 21: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 27: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 27 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 41: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 41 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 61: ......