24
ANTI-MASKING LEARNING PROCEDURE
-
PREPARING THE MASKING CHANNEL
FOR OPERATION (Obligatory for
proper Anti-masking operation!!!)
To enable proper operation of the masking
detection (Anti-masking), it is first
compulsory that the detector study and
analyze the environmental conditions of its
protected area.
Study Procedure to be performed in three
cases:
1.
Upon connecting the power supply to
the detector.
2.
Upon changing the position of DIP
switch No. 3 (Anti-masking sensitivity).
3.
Upon relocating the internal unit
on the detector’s back panel or upon
changing the shutter opening on the
lens support.
The study procedure in the first & second
cases
(1, 2)
-
If the detector’s case isn't closed, close it
immediately (within 15 seconds
maximum).
-
Keep away from detector’s front (at least
1 meter) until the study procedure
is complete, about 90 seconds.
- During the study procedure, the Green
and Yellow LED indicators will blink
together rapidly for about 45 seconds,
and right afterwards the Green LED