PERFORM A TEST
The test must be carried out when
detector's case is closed and the LED
indicators are enabled (DIP switch No.1
switched to ON, page 20).
Test procedure for human movement
detection (Alarm):
The required action:
Walk in the protected area.
Compulsory reaction of the detector:
Upon each detection event, the Alarm
Relay, left Red LED and Yellow LED
indicators will operate for 2 seconds
(default time).
- Left Red + Yellow LED indicators are
blinking
alternately
, meaning:
The detector operates according to the
mechanical settings, meaning according
the DIP switch and trimmers that set the
detection sensitivity (page 4).
- Left Red + Yellow LED indicators are
blinking
together
, meaning:
Alarm when the detector is enabled to
work with the Remote Control RM1, which
can be purchased separately (page 20).