2
5
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYP
AD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GA
TE DISABLE
Power
12 VDC
OR
24 VDC
Radio Power
12 VDC
OR
24 VDC
Photocell Power
Card Reader
CLOSE
Cycle Photocells
ONLY.
See page 14 & 32.
IS NOT
UL 325 entrapment protection type B1.
OPEN
Cycle
Photocells
ONLY.
Separate
power
for Devices.
Keypad
Photo Cell (N.O.)
Photocell (N.O.)
Edge 1
(N.O.)
Edge 2
(N.O.)
24V
RS-485
RS-485
250 mA Max.
Stop
GND
GND
GND
Key Switch
Telephone Entry
3-Button
Station
See page 32.
Additional
Reset Button
See page 32.
Gate Disable
Switch or Timer
See page 31.
Primary/Single Operator
Connect to MC-100 motor controller.
See pages 21 & 33.
Optional Key Switch
See page 22.
Optional
Control Box
Key Switch
See page 22.
MC-100 Motor Controller
See page 17
Secondary Operator
Connect to MC-100
See pages 21 & 33.
Radio Receivers
See page 28.
In-Ground Loops
See page 29.
Loop Detectors
See page 29.
Safety Loops Wired in series
Emergency OPEN
(Overrides gate
disable switch)
MAX OPEN
(Overrides gate
disable switch)
Center
Loop
Safety
Loo
p
Safety
Loop
Exit
Loop
Gate Tamper:
See page 30.
24V Power for Matrix 1 from
Primary/Single
operator
ONLY
.
See pages 17 & 33.
ID Plug:
See page 30
ID Plug Error LED. See page 30
4-Wire
Radi
o
3-Wire
Radio
ON
OF
F
ON
1
2
3
4
5
6
7
8
5 =
Optimum Sens
.
=
Inc
rease
Sens.
=
Decrease Sens.
DE
FLECTOMETER
POWER
ON =
Nor
mal Powe
r
OFF=
No Po
wer
LED
INDICA
TO
RS
DETEC
T
ON
= D
etect
OFF= N
o D
etec
t
2 Hz
Fla
sh=De
lay T
iming
SW1
SW
2 Frequ
en
cy
ON
ON =
Low
ON
OFF
= Medium
-Low
OFF
ON
= Medi
um-High
OFF
OFF
= Hi
gh
SW4
SW
5 O
utput
B
ON
ON = Pu
lse
on Entr
y
ON
OFF
= B sam
e as
A
OFF
ON
= Pu
lse
on Ex
it
OFF
OFF
= Loop
Faul
t
SW
3
ON
= Fail
Se
cure
OFF
= Fail
Sa
fe
SW
6
ON
= 2 Second Delay
OFF
=
No
Dela
y
SW
7
ON
=
Nor
mal
Presenc
e
OFF
=
Infini
te Presence
SW
8
ON
= Sensitivit
y Boos
t
OFF
=
No Sensiti
vity Boos
t
Loop
Fa
ult
1 Fl
ash
= Open
Loop
2 Flas
hes=
Sho
rted Loo
p
3 Flash
es=25%
ch
ange
of
Indu
ctanc
e
Both L
ED’
s Fl
ashi
ng=
Cu
rren
t Loo
p Fa
ult
PWR
LED
Fla
shin
g=
Prev
ious
Loop
Fa
ult
EDI
Tel: 480.9
68.640
7
DE
FLECTO
METER
SEN
S
RESE
T
POW
ER
DETEC
T
ED
I
SEN
S
LMA180
0
OPTIONS
1
2
3
4
5
6
7
8
O
N
UL LED Indicators
ONLY
.
See page 30.
Control Box
Alarm Reset Button
Strobe Light
See page 32
Emergency/Security Devices
Security Device
Security Device
Normal Opening Devices
Normal
Opening
Device
Normal
Opening
Device
GA
TE OPE
N
GA
TE CLOS
ED
UL 325
Entrapment
Protection
Type B1
See
page 14.
Maglock Connection:
Must be specifically
wired,
See page 29.
Reverse Edges: See page 14.
Connect to Edge 1 and/or Edge 2.
UL 325 entrapment protection type B2.
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo Cell
GND
Jog R
T
Jog L
T
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
matrix 1
PR
ESS
to R
ESET
Motion
Sensor
Security
Camera
Gate Status:
See page 32
.
Dry Contact
(N.O.)
Dry Contact (N.O.)
(N.O.)
(N.O.)
wiring Overview
See page 30.
Control
Box
ma
trix 1