background image

3

5

Adjustments

release handle clamp

Tighten the Adjustment bolt until desired result is achieved. 
The release handle clamp has been factory adjusted and 

SHOULD NOT

 need any adjustment.

IMPORTANT:

 The 

red handle MUST BE FIRMLY secure in the 

HORIZONTAL position

.

NOTE:

 When limit tabs are already set and the release handle is put 

back in the secure position but the gate is 

NOT

 in the full open or close 

position, the operator will 

automatically

 re-align the gate’s open and 

close tabs. 

No readjustment is necessary

.

After Release Handle Clamp is in the SECURE HORIZONTAL 
position:

Pull the arm. 

NO slippage should occur.

If it does, readjust.

Adjustment

Bolt

factory set bolt

DO NOT adjust

adj

ust

 bo

lt

for

 firm 

grip

Arm

Adjustment:

Re-Attach to Operator:

Limit Pin

Limit Tabs

Slot

Release Handle Clamp

Limit pin 

MUST 

fit into slot in bottom of 

release handle clamp 

directly under the 

arm

 when reattaching arm to operator.

IMPORTANT:

 

 The arm 

MUST

 

NOT

 slip 

when the gate is cycling or the gate 

OPEN

 

and 

CLOSE

 limit positions will 

NOT

 be 

LEARNED

. Gate speed will remain slow if 

gate positions are 

NOT

 learned.

Release Handle Clamp 

MUST

 be  

HORIZONTAL

 when 

FIRMLY

 secured.

NO

Содержание Max Phantom 2000

Страница 1: ...Installation and Owners Manual www max us com 4009963 High Traffic Commercial Brushless DC Low Profile Swing Gate Operator Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA...

Страница 2: ......

Страница 3: ...Matrix 1 Overview Wiring Overview Primary Gate Open Left Open Right Close Timer Selectable Gate Speed Control Battery Back Up Mode Anti Tailgate Single Pass Anti Tailgate Radio Receiver Radio Safety P...

Страница 4: ...of Operation Class I II III IV Gate Type Vehicular Swing Gate Max Gate Weight Length 2000lbs 15 ft or 1500 lbs 20 ft 90 Opening Time 16 selectable speeds from approximately 11 5 sec to 20 sec dependi...

Страница 5: ...ed via supervision by security personnel The same type of device shall not be utilized for both the primary and the secondary entrapment protection means Use of a single device to cover both the openi...

Страница 6: ...and or Reset button must be located in the line of sight of the gate Activation of the reset control shall not cause the operator to start H A minimum of two 2 WARNING SIGNS shall be installed one on...

Страница 7: ...m accidentally opening and or closing on vehicles in the gate s path Entrapment Protection Photocell Helps guard against the opening gate from entrapment Closing Gate Protection Photocell Helps protec...

Страница 8: ...www max us com Made in USA BATTERY PACK TO MOTOR CONTROLLER AC ON POWER OFF MAX PS 24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC 100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensiti...

Страница 9: ...R traffic ONLY Pedestrians MUST use a separate entrance Install appropriate entrapment protection safety devices for the OPENING direction and CLOSING direction of gate cycling Install in ground SAFET...

Страница 10: ...o the GATE OPERATOR See page 14 CLOSING cycle protection device wires photocells to the CONTROL BOX See page 14 In ground loop wires to the CONTROL BOX See page 15 Conduit Guidelines and Suggestions S...

Страница 11: ...hotocell OPENING Cycle ONLY Photocell OPENING Cycle ONLY Sensing Edges Entrapment Area Entrapment Area Control Box RS 485 Optional Key Switch to Control Box Input Power Input Power Conduit REQUIRED Ru...

Страница 12: ...K TO MOTOR CONTROLLER AC ON POWER OFF MAX PS 24 POWER SUPPLY FUSE 7 AMP IN Made in USA Power INPUTS MC 100 JOG RIGHT JOG LEFT UL Entrap Matrix On Line ERD Sensitivity Photo Cell Limit SW On Line Edge...

Страница 13: ...put Voltage 115VAC or 230VAC disc on ne ct po wer be fore se rvicing un it W ARNIN G W ARNIN G HIGH HIGH VOLTAGE VOLTAGE warranty VOIDED if label is REMOVED Power Solar In Connector Wire Nuts MAX Magi...

Страница 14: ...d separately Solar Panel must be mounted facing south It must get full sunlight throughout the day NO shadow obstructions MAX Solar Kit Power Solar In Connector Wire Nuts MAX Solar Power Kit Solar Pan...

Страница 15: ...rance Moving Gate Can Cause Serious Injury or Death KEEP CLEAR Gate may move at any time without prior warning Do not let children operate the gate or play in the gate area This entrance is for vehicl...

Страница 16: ...han 16 then secondary entrapment protection is REQUIRED in this area CLOSING Cycle NOTE Additional CLOSING Cycle Photocells can be installed anywhere needed Run all additional CLOSING Cycle photocell...

Страница 17: ...1 Wiring Safety loops need to be wired in series MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFET...

Страница 18: ...r ER D M in M ax Se ns iti vit y W A R N I N G W A R N I N G c o n n e c t c h a s s is t o g r o u n d r o d f o r li g h t n in g p r o t e c t io n Check with local building department prior to ins...

Страница 19: ...ively Battery IN Error LED Lights when there is a battery connection problem Make sure battery plug 1 is plugged into BATTERY IN port or there is no damaged or loose wires MOTOR OVERLOAD LED Excessive...

Страница 20: ...t of the gate operator The ground point must be at an electrical panel a metallic cold water pipe that runs in the earth or a grounding rod Ground Rod within 10 ft of operator WARNING WARNING connect...

Страница 21: ...roperly GROUNDED Pos GND Polarity Matters Ground Rod within 10 ft of Box NOTE Consult city codes for AC line wiring A MAX Magic Box Kit sold separately is required to remotely install the MAX PS 24 Po...

Страница 22: ...erators have been installed It replaces the MAX BC 7 Battery module in the operator s battery position see page 43 Operator cables reconnect to the same plugs on the BC 36 as they did on the BC 7 batt...

Страница 23: ...RS 485 connector Schematics on page 38 of manual shows where all plugs are located to re install MAX MC 100 motor controller 115V AC ON PO W ER OF F M AX PS 2 4 PO W ER SU PP LY FU SE 7 AM P IN Ma de...

Страница 24: ...ntrol Box Key Switch Primary Single Secondary Key Switch Terminal 3 Wires to Key Switch 3 Wires to Key Switch Primary Single Open LEFT PRIMARY SECONDARY OPEN RIGHT OPEN LEFT INSIDE Property OUTSIDE Pr...

Страница 25: ...X OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MAX BC 7 Battery Module Wiring operator turn on off operator power Turn AC Power Switch ON A A B B C C D D E E F F G G H H I I J J K K T...

Страница 26: ...Loop a closing gate will PAUSE if a second vehicle attempts to tailgate The second vehicle must then back off the safety loop for the gate to continue closing A new radio signal will open the gate Wh...

Страница 27: ...oop Safety Loop Safety Loop Exit Loop Gate Tamper See page 30 24V Power for Matrix 1 from Primary Single operator ONLY See pages 17 33 ID Plug See page 30 ID Plug Error LED See page 30 4 Wire Radio 3...

Страница 28: ...ssive click up to 60 sec MAX NOTE 1 2 sec MIN position is recommended for High Traffic areas gate close timer MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MA...

Страница 29: ...L GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MOTOR ON LINE LIMIT SWITCH ON LINE SAFETY ANTI TAILGATE OFF ON AUTHORIZED Vehicle UNAUTH...

Страница 30: ...ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MIN MAX 12VDC GN...

Страница 31: ...ere is an error with the corresponding loop detector MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SA...

Страница 32: ...EED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN CLOSE CONTROLS BATTERY BACK UP MODE MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Ta...

Страница 33: ...FF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MAX 12VDC GND 24VDC GND MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE...

Страница 34: ...4 wire 3 Button Station or an additional External RESET Button to be connected Corresponding LEDs will light when each button is activated OPEN COM CLOSE GATE STATUS GATE OPEN GATE CLOSED OPEN STOP S...

Страница 35: ...rator s limit switch that the Matrix 1 is successfully communicating with MOTOR ON LINE LEDs will light for each gate operator s MC 100 Motor Controller that the Matrix 1 is successfully communicating...

Страница 36: ...PEN Limit switch contact point CLOSED Limit switch contact point IMPORTANT Manually Release arm and move the gate to the desired OPEN and CLOSED positions to adjust the limit tabs Make sure power is O...

Страница 37: ...eadjustment is necessary After Release Handle Clamp is in the SECURE HORIZONTAL position Pull the arm NO slippage should occur If it does readjust Adjustment Bolt factory set bolt DO NOT adjust adjust...

Страница 38: ...is equipped with an ERD Sensor Electronic Reversing Device Type A that functions as the primary entrapment protection according to UL 325 standards The gate will reverse direction after encountering...

Страница 39: ...home owner must call a qualified professional gate operator technician for any repairs and modifications The gate operator is virtually maintenance free to an end user home owner minimal maintenance i...

Страница 40: ...T MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN CLOSE CONTROLS BATTERY BACK UP MODE MATRIX 1 PHOTOCELL...

Страница 41: ...hood and remove it 2 Make sure ALL power is OFF to operator 1 Pull red handle up and move gate 3 maintenance manual gate release Arm WARNING WARNING NEVER grasp the arm to move gate Pinch Point Arm AL...

Страница 42: ...ll PAUSE in the position where the second obstruction occurred CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the alarm reset button on the control box to shut off the alarm and reset the gate N...

Страница 43: ...t Clamp Assembly Operator cover with nameplate Swing arm T Bar Output collar and rings Output Shaft 7Ahr Battery Module Limit Switch Assembly Power Supply Assembly 900 1 Double Gear Box DC Brushless M...

Страница 44: ...e without an RMA number Shipping charges to and from the factory service center for warranty repairs are the responsibility of the customer Repair or replacement of any warranty items is made at the s...

Страница 45: ...ry power your performance might vary max BC 36 phantom battery module optional The red release handle clamp is lifted and the gate is pushed open from the closed position without authorization The gat...

Страница 46: ...O PRI_MC Fully Open Posi on Learned Fri 07 11 2014 10 58 53 INFO SEC_MC Fully Open Posi on Learned Fri 07 11 2014 10 57 40 INFO PRI_CIO Communica on Established Fri 07 11 2014 10 57 38 ENTRAP PRI_MC P...

Страница 47: ...45...

Страница 48: ...ch Ca 92610 Tel 949 699 0220 www max us com 4009963 High Traffic Commercial Brushless DC Low Profile Swing Gate Operator Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA ST...

Отзывы: