17
Power
INPUTS
MC-100
JOG
RIGHT
JOG
LEFT
UL
Entrap
Matrix
On Line
ERD
Sensitivity
Photo
Cell
Limit SW
On Line
Edge 2
Edge 1
Edge 1
Edge 2
Photo Cell
GND
Jog R
T
Jog L
T
MOTOR OVERLOAD
Motor Controller
ERD
Min
Max
Sensitivity
POWE
R
IN
POWER
/SOLAR
IN
BA
TTER
Y
IN
www
.max.us.com
Ma
de in
USA
BA
TTER
Y
PACK
TO MOTOR
CO
NTROLLER
E
1/2
Batter
y Vo
ltage
Replac
e
Batter
y
ON/OFF
Batte
ry
TES
T
Batte
ry
Batte
ry IN
Error
F
MAX BC-7
Batter
y Modul
e
IMPORT
ANT
connect to
“BA
TT
ER
Y IN”
before use
ALARM
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
LIMIT
SWITCH
BATTERY
PACK
MOTOR
INPUTS
POWER IN
MOTOR
www.max.us.com
Wiring operator
3
4
5
6
7
1
1
2
3
4
5
6
7
A
B
C
D
E
F
G
H
I
J
K
L
M
A
B
C
D
E
F
G
I
K
H
J
L
M
2
BATTERY Plug:
MUST
be plugged into
BATTERY IN
port
Before
use.
POWER/SOLAR IN Port:
MAX PS-24 Power Supply connection.
Battery Voltage LEDs:
Show amount of battery power available.
LEDs are always ON when using AC power. Test battery button must be
pressed to show battery power when using battery power ONLY.
ON/OFF Battery Button:
IMPORTANT:
Battery power
automatically
turns
ON
when MAX PS-24 Power
Supply
AC POWER
Switch
is turned
ON
.
To turn OFF
ALL POWER
to operator:
1.
Turn OFF
AC POWER Switch
on MAX PS-24 Power Supply.
Battery
power
remains ON
.
2.
WAIT
for 15 seconds.
3. Press and HOLD
(approx. 5 seconds) the
YELLOW
ON/OFF BATTERY
button until MAX BC-7 LEDs turn
ON
, then release button.
LEDs will turn
OFF
.
Replace Battery LED:
Replace battery when lit.
TEST Battery Button:
Press to show amount of battery power available when
using battery power ONLY (Battery voltage LEDs will light respectively).
Battery IN Error LED:
Lights when there is a battery connection problem.
Make sure battery plug #1 is plugged into BATTERY IN port or there is no
damaged or loose wires.
MOTOR OVERLOAD LED:
Excessive current being drawn by motor when lit.
ERD LED:
ERD sensor has been activated when lit.
ERD Sensitivity Knob:
16 selectable sensitivity settings of ERD sensor.
ERD Sensitivity LED:
MAX sensitivity reached when lit.
Jog LEFT/RIGHT Buttons:
Push and
HOLD
buttons accordingly to move the gate (release the button to
stop gate).
WARNING:
Avoid moving arm while using Jog buttons.
INPUTS:
Jog LT/RT:
Connects to optional key switch on Control Box.
GND:
Low Voltage Common connection.
Edge 1:
Connects to a Sensing Edge. Multiple sensing edges can be
connected.
Edge 2:
Connects to a second Sensing Edge. Multiple sensing edges can be
connected.
PHOTOCELL:
Connects to a UL 325 Standard
OPENING Cycle
photocell
ONLY
. Multiple
OPENING Cycle
photocells can be connected.
Matrix On Line LED:
Gate operator is successfully communicating with
Matrix 1 when lit.
Limit SW On Line LED:
Limit Switch Box is successfully communicating
with MC-100 Motor Controller when lit.
Edge 1 LED:
Reversing Edge 1 input has been activated when lit.
Edge 2 LED:
Reversing Edge 2 input has been activated when lit.
UL Entrap LED:
Edge1/Edge2/Photocell input has been activated when lit.
Photocell LED:
Photocell input has been activated when lit.
Power LED:
Low voltage power is connected when lit.
Edge 1
(N.O.)
Edge 2
(N.O.)
GND
24V
RS-485
GND
Sensing Edges
To Matrix 1
Gate Operator System Overview continued
MAX MC-100 Motor Controller
MAX BC-7 Battery Module
DUAL GATE OPERATORS NOTE:
Connect
EACH
photocell/reverse
edge to the
corresponding gate operator
. See page 9.
OPENING
Cycle
Entrapment
Photocells
ONLY.
24V
Power.
Photocell (N.O.)
GND
GND
24V
Optional Electronic
Open/Close
Key Switch,
See page 22.