CCpilot VC
2.2
Common templates
2017-03-13
w ww.maximatecc.com
27
7.2.
Environmental specifications
Environmental Test
Standard
Notes
Dry Heat
IEC 60068-2-2:2007
Operating: +70°C, 24h
Storage:
+85°C, 24h
Damp Heat
IEC 60068-2-30:2005
Operation: +25°C / +55°C
>93% RH 2*24h
Cold
IEC 60068-2-1:2007
Operating: -25°C, 24h
Storage:
-40°C, 24h
Change of temperature
IEC 60068-2-14:2009
-20°C to +70°C, 5C/min
3hr hold time, 20 cycles
Vibration
IEC 60068-2-64:2008
0,02 g2/Hz 5-500 Hz 3x 3h
Shock
IEC 60068-2-27:2009
30 g / 11ms 3x ±10 bumps
EM C Electrical Transient
ISO 7637-2:2011
Pulse 1: -50V
2: +25V
3a: -35V
3b: +35V
4: -5V
5: +70V
EM C Immunity, ESD
ISO 10605:2008
±8 kV air, ±6 kV contact
EM C RF Immunity, Radiated
1)
ISO 11452-2:2004
RF electromagnetic field
200-1000MHz, 30V/m
EM C RF Immunity, Induced
1)
ISO 11452-4:2005/Cor.1:2009
Bulk Current Injection
20-200MHz, 60 mA
EM C Radiated Emission
1)
ISO 14982:2009
Narrow b. Broad b.
M Hz
[dBµV/m] [dBµV/m]
30-75
54-44
64-54
75-400
44-55
54-65
400-1000
55
65
Enclosure Ingress Protection
IEC 60529:2014
IP66
1)
Requires shielded cables for Ethernet, USB and Video interfaces.
Env ironmental tests are performed at 24 V
DC
supply voltage unless otherwise required. The
env ironmental tolerance may be affected by external factors like mounting, omitting the use of
shielded cables etc.
Any changes or modifications to the device not expressly approved by maximatecc could void the
env ironmental classification, warranty as well as user's authority to operate the equipment.