MAX32660 User Guide
Maxim Integrated
Page 151 of 195
I
2
C Interrupt Enable 0 Register
I2Cn_INTEN0
[0x000C]
Bits
Name
Access
Reset
Description
4
rxthie
R/W
0
RX FIFO Threshold Level Interrupt Enable
Set this field to enable interrupt events when an RX FIFO threshold event occurs.
0: Interrupt disabled.
1: Interrupt enabled.
3
amie
R/W
0
Slave Mode Incoming Address Match Interrupt Enable
Set this field to enable the slave mode address match interrupt event.
0: Interrupt disabled.
1: Interrupt enabled.
2
gcie
R/W
0
Slave Mode General Call Address Match Received Interrupt Enable
Set this field to enable the slave mode general call address match received interrupt
event.
0: Interrupt disabled.
1: Interrupt enabled.
1
irxmie
R/W
0
Interactive Receive Interrupt Enable
Set this field to enable the interactive receive interrupt event.
0: Interrupt disabled.
1: Interrupt enabled.
0
doneie
R/W
0
Transfer Complete Interrupt Enable
Set this field to enable the transfer complete interrupt event.
0: Interrupt disabled.
1: Interrupt enabled.
Table 12-8: I
2
C Interrupt Status Flags 1 Registers
I
2
C Interrupt Status Flags 1 Register
I2Cn_INTFL1
[0x0010]
Bits
Name
Access
Reset
Description
31:2
-
R/W
-
Reserved for Future Use
Do not modify this field.
1
txufi
R/W1C
0
Slave Mode: TX FIFO Underflow Status Flag
In Slave Mode operation, the hardware sets this flag automatically if the TX FIFO is
empty and the master requests more data by sending an ACK after the previous byte
transferred.
0: Slave mode TX FIFO underflow condition has not occurred.
1: Slave mode TX FIFO underflow condition occurred.
0
rxofi
R/W1C
0
Slave Mode: RX FIFO Overflow Status Flag
In Slave Mode operation, the hardware sets this flag automatically when an RX FIFO
overflow occurs. Write 1 to clear. Writing 0 has no effect.
0: Slave mode RX FIFO overflow event has not occurred.
1: Slave mode RX FIFO overflow condition occurred (data lost).
Table 12-9: I
2
C Interrupt Enable Registers 1
I
2
C Interrupt Enable 1 Register
I2Cn_INTEN1
[0x0014]
Bits
Name
Access
Reset
Description
31:2
-
R/W
0
Reserved for Future Use
Do not modify this field.
1
txufie
R/W
0
Slave Mode TX FIFO Underflow Interrupt Enable
In slave mode operation, set this field to enable the TX FIFO underflow interrupt.
0: Interrupt disabled.
1: Interrupt enabled.