37
MAXDATA Workstation Fusion 7000
System Cooling Fans Do Not Rotate Properly
If the system cooling fans are not operating properly, system components could be damaged.
Check the following:
q
Is AC power available at the wall outlet?
q
Is the system power cord properly connected to the system and the wall outlet?
q
Did you press the power button?
q
Is the power on light lit?
q
Have any of the fan motors stopped (use the Workstation management subsystem to
check the fan status)?
q
Are the fan power connectors properly connected to the Workstation board?
q
Is the cable from the front panel board connected to the Workstation board?
q
Are all standoffs in the proper location and not touching any through hole components,
causing a potential short?
q
Are the power supply cables properly connected to the Workstation board?
q
Are there any shorted wires caused by pinched-cables or power connector plugs forced
into power connector sockets the wrong way?
If the switches and connections are correct and AC power is available at the wall outlet, contact your
service representative or authorized dealer for help.
Diskette Drive Activity Light Does Not Light
Check the following:
q
Are the diskette drive’s power and signal cables properly installed?
q
Are all relevant switches and jumpers on the diskette drive set correctly?
q
Is the diskette drive properly configured?
q
Is the diskette drive activity light always on? If so, the signal cable may be plugged in
incorrectly.
If you are using the onboard diskette controller, use the BIOS setup to make sure that “Onboard
Floppy” is set to “Enabled”. If you are using an add-in diskette controller, make sure that “Onboard
Floppy” is set to “Disabled”.
If the problem persists, there may be a problem with the diskette drive, Workstation board, or drive
signal cable. Contact your service representative or authorized dealer for help.
Hard Disk Drive Activity Light Does Not Light
The hard disk drive activity light is not connected to the mainboard front panel.
CD-ROM Drive Activity Light Does Not Light
Check the following:
q
Are the CD-ROM drive’s power and signal cables properly installed?
q
Are all relevant switches and jumpers on the drive set correctly?
q
Is the drive properly configured?