9.02
TI013G0008
PROBLEM
CAUSE
SOLUTION
C. Oil
Excessive oil consumption;
the level lowers too quickly; oil
is detected within the network.
The air-oil separator
fi
lter is
clogged.
Replace the
fi
lter.
(See chapter 7)
D. Temperature
The compressor stops due to
its own over-heating.
The radiator or the
fi
lter of
the cooling air is dirty; the
environmental temperature is
excessive for the compressor
operation.
Verify the cause and remove
the problem.
(See chapter 7)
The compressor stops due to
the over-heating of the motor.
Excessive working pressure.
Verify the setting and re-set to
the design value for the machi-
ne.
(See chapter 7)
The main motor cooling is
insuf
fi
cient; the cooling air is
either too hot or too little.
Verify the environmental con-
ditions and the condition of the
fi
ltering panel.
(See chapter 3 and 7)
E. NOISE LEVEL
Belts are noisy.
Belts are not tightened enou-
gh.
Correcly tighten the belts.
(see chapter 7).
Troubleshooting
Содержание BLADE 4