7
Command reference
51
VSET? Command
This command allows receiving the setting value of output voltage with 0.0 to rated voltage
(increment of 0.01V)
(Syntax)
VSET?
(in case of 20V/20A)
(Return)
①
VSET=20.0
Set to 20.0V
②
VSET=12.34
Set to 12.34V
③
VSET=0.8
Set to 0.8V
(Description)
0 value of 2 decimal point is not displayed(Return
③
)
※
Minimum setting value of VSET? command is different for each
model ,RK(400W/800W/1200W)/REK/REKJ.
(See Section “
7-3
Minimum setting / return value for each command”.)
ISET? Command
This command allows receiving the setting value of output current with 0.0 to rated voltage
(increment of 0.01A)
(Syntax)
ISET?
(in case of 20V/20A)
(Return)
①
ISET=20.0
Set to 20.0A
②
ISET=12.34
Set to 12.34A
③
ISET=2.5
Set to 2.5A
(Description)
0 value of 2 decimal point is not displayed(Return
③
)
※
Minimum setting value of ISET? command is different for each
model ,RK(400W/800W/1200W)/REK/REKJ.
(See Section “
7-3
Minimum setting / return value for each command”.)
OVPSET? Command
This command allows receiving the setting value of over voltage protection value with 0.0 to rated
voltage (increment of 0.01V)
Maximum over voltage protection value = maximum rated voltage x 110%
(Syntax)
OVPSET? (in case of 20V/20A)
①
OVPSET=22
Set to 22V
②
OVPSET=12.34
Set to 12.34V
③
OVPSET=2.3
Set to 2.3V
(Description)
0 value of 2 decimal point is not displayed(Return
③
)
OCPSET? Command
This command allows receiving the setting value of over current protection value with 0.0 to rated
current (increment of 0.01A)
Maximum over current protection value = maximum rated current x 110%
(Syntax)
OCPSET? (in case of 20V/20A)
①
OCPSET=22
Set to 22A
②
OCPSET=12.34
Set to 12.34A
③
OCPSET=2.3
Set to 2.3A
(Description)
0 value of 2 decimal point is not displayed(Return
③
)