7
Command reference
40
CH2 Command
This command programs over voltage protection with 00
H
to FF
H
(8bit)
Maximum over voltage protection value = maximum rated voltage x 110%
(Syntax)
①
CH2
FF
(Over voltage protection value) = (maximum over voltage
protection
value)
②
CH2
7F
(Over voltage protection value) = (half of maximum over
voltage protection value)
③
CH2
F
Same as “CH2
0F”
④
CH2
123
Over voltage protection value does not change
(Default) CH2
FF
(Description)
It ignores as a parameter of a number over 2 digits (Syntax
④
)
Over voltage protection does not work when setting is under 03
H
Featuring multiple command
CH7 Command
This command programs over current protection with 00
H
to FF
H
(8bit)
Maximum over current protection value = maximum rated current x 110%
(Syntax)
①
CH7
FF
(Over current protection value) = (maximum over current
protection
value)
②
CH7
7F
(Over current protection value) = (half of maximum over
current protection value)
③
CH7
F
Same as “CH7
0F”
④
CH7
123
Over current protection value does not change
(Default) CH7
FF
(Description)
It ignores as a parameter of a number over 2 digits (Syntax
④
)
Over voltage protection does not work when setting is under 03
H
Featuring multiple command
Содержание 35