23
CHAPTER 8: TRoUblESHooTINg
8.7 TRoUblESHooTINg - ERRoR 0248
fIgURE A
ERRoR CoDE 0248
1) SyMPToM:
0248 –Battery disconnection or fail. (When it is power on, LCB battery voltage is less than 6 voltage.)
2) SolUTIoN:
1) Check the battery wire connection between the battery and LCB (Figure A).
2) Check the voltage output of the battery. If it is less than 6V (Figure B), replace the battery.
3) If the battery voltage is over 6V or, if the battery does not resolve the issue, replace the LCB.
fIgURE b
Содержание S5X-04
Страница 1: ...S 5 x 0 4 S T E P P E R S E R V I C E M A N U A l...
Страница 17: ...14 8 1 electrical diagrams Chapter 8 Troubleshooting HURES5x C Electrical block diagram...
Страница 18: ...15 8 1 Electrical Diagram CONTINUED Chapter 8 Troubleshooting s5x F Electrical block diagram...
Страница 19: ...16 8 1 electrical diagramS CONTINUED Pulse Sensor Wire Chapter 8 Troubleshooting...
Страница 23: ...20 8 4 LCB wiring connectionS CHAPTER 8 Troubleshooting...
Страница 62: ...59 10 3 Assembly Instructions Continued step 3 Chapter 10 Stepper SpecificationS and Assembly Guide...
Страница 63: ...60 step 4 10 3 ASSEMBLY INSTRUCTIONS CONTINUED Chapter 10 Stepper Specifications and Assembly Guide...
Страница 64: ...61 final assembly 10 3 assembly instructions continued Chapter 10 Stepper SpecificationS and Assembly Guide...
Страница 72: ...69 NOTES...