18
8.2 ERRoR CoDES oN THE CoNSolE
CoDE
ClASS
DESCRIPTIoN
SolUTIoN
0x0441
B
When the UCB implements
a command, the LCB is not
receiving this command.
Check the machine type in
Engineering Mode. Check the
console cable connections at the
UCB and LCB.
0x02AB
C
Machine type error.
Set the correct machine type in
Engineering Mode.
0x02B3
C
Resistance type error.
Set the correct machine type in
Engineering Mode.
0x04A0
C
Digital Communication Failure.
LCB has no return message for
the UCB for 3 seconds.
Check the console cable
connections at the UCB and
LCB. Replace the UCB or LCB
as needed.
0x0201
A
Low voltage on the battery
(voltage under 11.2V).
Charge the battery by running or
by plugging in the AC adapter.
0x0247
B
LCB failed (memory write error /
feedback ADC error).
Replace the LCB.
0x0248
B
Battery failure or disconnection
(Voltage under 8V or over 15V).
Check the wire connections at
the battery. Replace the battery.
ClASS C ERRoRS WIll DISPlAy oN THE CoNSolE.
ClASS A oR b ERRoRS WIll oNly DISPlAy IN SERVICE MoDE 5.
CHAPTER 8: TRoUblESHooTINg
Содержание S5X-04
Страница 1: ...S 5 x 0 4 S T E P P E R S E R V I C E M A N U A l...
Страница 17: ...14 8 1 electrical diagrams Chapter 8 Troubleshooting HURES5x C Electrical block diagram...
Страница 18: ...15 8 1 Electrical Diagram CONTINUED Chapter 8 Troubleshooting s5x F Electrical block diagram...
Страница 19: ...16 8 1 electrical diagramS CONTINUED Pulse Sensor Wire Chapter 8 Troubleshooting...
Страница 23: ...20 8 4 LCB wiring connectionS CHAPTER 8 Troubleshooting...
Страница 62: ...59 10 3 Assembly Instructions Continued step 3 Chapter 10 Stepper SpecificationS and Assembly Guide...
Страница 63: ...60 step 4 10 3 ASSEMBLY INSTRUCTIONS CONTINUED Chapter 10 Stepper Specifications and Assembly Guide...
Страница 64: ...61 final assembly 10 3 assembly instructions continued Chapter 10 Stepper SpecificationS and Assembly Guide...
Страница 72: ...69 NOTES...