Operating instructions
Pressurised air grease pump
pneuMato-55
MATO
GmbH & Co. KG
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:+49(0)6108-906-0 / Fax:+49(0)6108-906-120
12
7
Tips for fault diagnostics:
Symptom
Possible cause
Rectification
Pump does not produce
any grease.
The container is empty.
The grease supply has been interrupted.
There is a lack of air pressure.
Suction sieve is dirty
Check level of the container.
Vent the pump.
Check supply line.
Clean suction sieve
The air motor of the
pump is working too
slowly
Suction screen is clogged
Filter at air inlet is clogged
Filter in the handle of the gun nozzle is
clogged
Connection pressure is too low
Clean suction sieve
Clean filter (see picture)
Clean filter
Correct pressure settings
Warning!
During the removal of the screw-nut, only hold in the area (20mm) directly
behind the washer.
8
Specifications:
Pressurised air pump pneuMATO
55
Size of device
10-25 kg
50 kg
200 kg
Pressure transfer
Max. delivery pressure at 8 bar compressed air
connection.
Air pressure min./max.
Volume level:
01:55
425 bar
3 – 8 bar
ca. 85
dB(A)
fluid temperature(lower temperatures are
possible, depending on the fluidity of the grease)
5°C bis +50°C
Thread
Air connection
Grease outlet
Suction tube diameter
Rp ¼“
R ¼“
40 mm
Suction tube length
495 mm
690 mm
885 mm
Weight
4.9 kg
5.6 kg
6.4 kg
Lubricants:
Grease up to the consistency of 2 (NLGI / Class 2 according to DIN 51818) can be used. Pastes
without lubricative properties (with abrasive emery parts) as well as grease or pastes that are
based on silicone oil and thickened with PTFE are not allowed to be used with this device.
9
Disposal
After termination of use the device is to be disposed of in an environmentally
friendly manner in accordance with applicable statutory provisions.
Grease-tainted parts do not belong in the dustbin!
The applicable regulations for the registration, installation and operation of equipment for
handling of substances hazardous to water are to be strictly observed by the operator (such as,
e.g., Federal Water Act, German Ordinance on Exposure to Substances Hazardous to Waters
and Technical Rules and Regulations for Flammable Liquids).
Suction
Washer
Nut
20mm
Air filter
Содержание pneuMATO-55
Страница 25: ...25...