background image

KNOW YOUR AIR COMPRESSOR WITH LCD DISPLAY COMPONENTS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A)  Air Compressor Pump & Electric Motor 

B) Air 

Tank 

C)  Digital Control Panel (see below for further detail) 

D)  Air Line Outlet 

E)  Pressure Relief Valve 

F)  Air Tank Drain Valve (drain after each day’s usage) 

G)  6 1/2"/1.98 m Power Cord 

 
 

A.  AIR COMPRESSOR PUMP & ELECTRIC MOTOR:

 The 

PUMP

 compresses the air and discharges it into the 

tank via the piston that moves up and down in the cylinder. The 

MOTOR

 is used to power the pump. It is 

equipped with a thermal overload protector and an automatic reset. If the motor overheats for any reason, the 
thermal overload protector will shut it down in order to prevent the motor from being damaged. The motor will 
automatically restart when it has cooled sufficiently. 

 

B. AIR 

TANK: 

The tank is where the compressed air is stored. 

 

C.  DIGITAL CONTROL PANEL: 

The digital control panel consists of the on/off button (

H

), tank pressure button (

I

), 

pressure adjustment (up) button (

J

),

 

pressure adjustment (down) button (

K

), pressure presetting button (90 PSI) 

(

L)

, pressure presetting button (30, 40, 60 PSI) (

M

), a LCD display window (

N

) and Tank pressure indicator (

O

).  

 

D.  AIR LINE OUTLET: 

The outlet with quick-connect coupler is connected to 1/4” (6.4 mm) NPT air hose. 

 

E. PRESSURE 

RELIEF 

VALVE: 

This valve is used to prevent system failure by draining pressure from the system 

if the control board does not shut down the motor when the pressure reaches the preset level. It will pop open 
automatically, or it can be activated manually by pulling the ring on the valve to release air pressure in the tank. 

 

F.  AIR TANK DRAIN VALVE: 

The drain valve is used to remove moisture from the air tank after the compressor is 

shut off. 

   

Do not attempt to open the drain valve when there is more than 10 PSI of air pressure in 

the tank. 

 

G. POWER 

CORD: 

This air compressor should be used on a nominal 120-volt grounded circuit. Use a 3-prong 

power cord that is equipped with a ground prong. Verify that the air compressor is plugged into an outlet that has 
the same configuration as the plug (see Figure 1 in page 6). Do not use an adaptor with this compressor.   

O

C

B

F

Digital Control Panel 

H) On/Off 

Button 

I)  Tank Pressure Button 

J)  Pressure adjustment (up) button 

K)  Pressure adjustment (down) button 

L)  Pressure pre-set button (90 PSI) 

M)  Pressure pre-set button (30, 40, 60 PSI); 

N) LCD 

Display 

window 

O)  Tank pressure indicator 

Содержание 058-7947-0

Страница 1: ...l Parts Missing or Damaged Questions Toll Free Help Line 1 800 689 9928 IMPORTANT Ensure that all users have read all safety rules and operating instructions carefully before using this product Keep t...

Страница 2: ...ST 13 ACCESSORIES 13 WARRANTY 14 SPECIFICATIONS Product Number 058 7947 0 Peak horsepower 5 0 HP Motor Type Universal 15 000 RPM Pump Type Oil Less Tank size 11 gallons 41 6 litres Air delivery SCFM 4...

Страница 3: ...ng parts could cause serious injury 5 RISK OF BURSTING Check the maximum pressure rating in the manual or the serial tag label The compressor outlet pressure must be regulated so that it does not exce...

Страница 4: ...and Tank pressure indicator O D AIR LINE OUTLET The outlet with quick connect coupler is connected to 1 4 6 4 mm NPT air hose E PRESSURE RELIEF VALVE This valve is used to prevent system failure by d...

Страница 5: ...pressure to a pre set PSI There are three pre set pressure levels 30 40 60 PSI Pressing the button for the first time sets directly to a pre set pressure 30 PSI Pressing for second time sets directly...

Страница 6: ...er or separately require more than the air compressor can deliver will void the compressor guarantee warranty EXTENSION CORDS Avoid the use of extension cords whenever possible If an extension cord mu...

Страница 7: ...g and freezing of water condensation d Place air compressor on the floor or a hard level surface The air compressor must be level to ensure proper drainage of the moisture in the tank 4 Connect an air...

Страница 8: ...injuries DO NOT touch the air compressor while it is running Allow it to cool before handling or servicing Keep children away from the air compressor at all times 3 Press the ON OFF button to the ON p...

Страница 9: ...structions TESTING FOR LEAKS Check that all connections are tight A small leak in any of the hoses or pipe connection will Substantially reduce the performance of your air compressor If you suspect a...

Страница 10: ...in pressure of pressure tank Check valve stuck open Remove and clean or replace Loose electrical connections Contact authorized service centre or store Compressor motor will not run or start Possible...

Страница 11: ...protector cuts out repeatedly Unit is plugged into an extension cord Remove extension cord Tip It is better to use a longer hose instead of an extension cord Dirt covered cooling surfaces Allow compre...

Страница 12: ...PARTS SCHEMATIC 12...

Страница 13: ...20 Tank 1 3 Handle 1 21 Interconnect cord 1 4 Bolt 3 22 Screw 1 5 Washer GB96 85 3 23 Elbow 1 6 Copper sealing ring 2 24 Check valve 1 7 Sponge filter 1 25 Quick connector 1 8 Transfer tube 1 26 Safe...

Страница 14: ...s or adjustments e this warranty will not apply where damage is caused by repairs made or attempted by others i e persons not authorized by the manufacturer f this warranty will not apply to any produ...

Отзывы: