background image

  PLEASE  READ  THE  FOLLOWING  INSTRUCTION 

CAREFULLY IN ORDER TO MAKE SURE THAT THE 

HEATER IS USED PROPERLY AND DOES NOT CAUSE 

MALFUNCTION.

►►

1. USE

Universal oil heater are suitable for heating big size buildings 

without central heating (shops, service stations, industrial build

-

ings,  warehouses,  inventory  buildings,  basements,  garages, 

etc.) The heater runs on most oils of mineral and plant origin, 

such as motor oils, heating oil, gear oils, hydraulic oils at a tem

-

perature of 15ºC and maximum ignition temperature not lower 

than 56ºC and density above 980 kg/m³.

 NOT TO BE USED WITH TRANSFORMER (INSU

-

LATING)  OILS.  THEY  MAY  CONTAIN  SUBSTANCES 

THAT CAN DAMAGE THE HEATER.

►►

2. STORAGE CONDITIONS

Universal  oil  heaters  should  be  stored  in  the  following  condi

-

tions:

temperature

-20 - +85°C

relative humidity

5-85%

pressure

800-1200hPa

free of dust

free of chemical pollutants

►►

3. CONDITIONS FOR USE

Universal  oil  heaters  should  be  operated  under  the  following 

conditions:

temperature

0 - 30°C

relative humidity

5-85%

pressure

800-1200hPa

environmental impact protection

IP21

appropriate ventilation of heated area √

►►

4. CHARACTERISTICS OF THE CONTROL PAN-

EL

 

► the heater may be regulated and set at 17 and 33 kW,

 

► protection against overheating the burner,

 

► protection against overflow of oil in the burner,

 

► automatic  retaining  of  previous  settings  in  case  of  power 

failure.

►►

5. SAFETY MEASURES

 

► Universal oil heater is connected to 230V/50Hz alternating 

current network. 

 

► Universal oil heater is equipped with two bimetallic sensors 

assuring safe and effective functioning of the device.

 

► Bimetallic sensor (FIG4/p1) in the burner triggers reaction in 

form of clenching contacts when the temperature in burner rises 

above 40°C and opening of contacts when the temperature falls 

below 35°C. 

 

► Second bimetallic sensor (FIG4/p2) is installed next to the 

blower fan with threshold temperature set at 90°C. Clenching of 

contacts, when threshold temperature is exceeded, causes that 

the burner immediately switches into the overheating mode (see 

point. 8 of the instruction).

 

► The heater is also equipped with weigh sensor placed under 

the overflow tank (the so-called overflow fuse) (FIG4/p3).

 

► When the tank is filled, the heater immediately switches into 

the overflow mode (see point 8 of the instruction).

 

► The control panel of the heater is factory - connected with 

other elements of the system (such as sensors, pump, and fan) 

and it is a safety requirement that during regular use there be no 

interference with covered and sealed part of the control panel 

as well as integrity of wiring. Any interference of unauthorized 

person may cause an electric shock (230V/50Hz) and burns.

►►

6. CONSTRUCTION OF CONTROL PANEL

 

► Fig. 1 Control panel

►►

7. INSTALLATION

When installing the heater, all local regulations are to be com

-

plied with, including regulations referring to national norms.

 

► Place the heater on flat surface made of concrete.

 

► Level the device in order to check if the heater is levelled 

correctly,  place  the  vaporising  pan  in  the  lower  part  of  the 

combustion chamber and pour a small amount (approximately 

250ml)  of  diesel  oil  onto  it. The  oil  should  stay  exactly  in  the 

middle of the pan.

 

► Install  current  stabilizer  (valve)  on  the  combustion  cham

-

ber’s outlet pipe in order to maintain constant draught inside the 

pipe during the operation.

 

► Install at least 5 meters long, smooth and temperature re

-

sistant  horizontal  flue  (not  aluminium  flue)  in  order  to  provide 

optimum draught.

 

► Check tightness of all joints, if necessary use the insulation 

tape.

 

► Make sure that the vaporising pan is placed centrally in the 

combustion chamber (FIG5/p3).

 

► Place  the  upper  ring  inside  the  combustion  chamber  with 

flange facing upwards and install the hot air pipe (FIG5/p2). 

TABLE OF CONTENTS

1...

USE

2...

STORAGE CONDITIONS

3...

CONDITIONS FOR USE

4...

CHARACTERISTICS OF THE CONTROL PANEL

5...

SAFETY MEASURES

6...

CONSTRUCTION OF THE CONTROL PANEL

7...

INSTALLATION

8...

FUNCTIONNING

9...

HOW TO OPERATE THE HEATER

10...

FAILURES AND REMEDIES

11...

TECHNICAL SPECIFICATIONS

BG

CZ

DE

FI

FR

GB

PL

RU

SE

SE

SI

SK

Содержание WA33C

Страница 1: ...S UNDWARTUNGSANLEITUNG K YTT JAHUOLTO OHJE MANUELD UTILISATIONETDEMAINTENANCE USERANDMAINTENANCEBOOK KNJI ICAOUPORABIIODR AVANJU HASZN LATI SKARBANTART SIK ZIK NYV HEFTEFORBRUKOGVEDLIKEHOLD INSTRUKCJA...

Страница 2: ...BG CZ DE FI FR GB HR HU NO PL RO RU SE Fig 1 Fig 2 BG CZ DE FI FR GB HR HU NO PL RO RU SE Fig 1 Fig 2 BG CZ DE FI FR GB HR HU NO PL RO RU SE Fig 1 Fig 2...

Страница 3: ...BG CZ DE FI FR GB HR HU NO PL RO RU SE Fig 4 Fig 3 start stop 1 2 3 4 5 6 7 8 BG CZ DE FI FR GB HR HU NO PL RO RU SE Fig 4 Fig 3 start stop 1 2 3 4 5 6 7 8...

Страница 4: ...BG CZ DE FI FR GB HR HU NO PL RO RU SE Fig 5 Fig 5...

Страница 5: ...temperature is exceeded causes that the burner immediately switches into the overheating mode see point 8 of the instruction The heater is also equipped with weigh sensor placed under the overflow ta...

Страница 6: ...r is heated up to 40 C the joints of thermostat placed next to com bustion chamber clutch activating the oil inlet pipe and blower fan The diode nr 5 pump on the control panel goes on blink ing for 30...

Страница 7: ...g up mode of the burner SHUTTING OFF Press Stop on the control panel pump stops feeding fuel onto the vaporising pan and ventilation fan works only until the burner has cooled off THE DEVICE MUST NOT...

Страница 8: ...did not reach desired temperature Wait until the burner cools down and relight Replace the thermostat 7 Overflow fuse is full Clean 8 Security thermostat STB does not work correctly or does not work...

Страница 9: ...t ha 35 C al esik A m sik bimet l rz kel nek FIG4 p2 hat r rt ke 90 C s a l gbef v ventill tor k zel ben tal lhat Abban az esetben ha megszak tan az ramk rt a hat r rt k t ll p sekor a k ly ha azonnal...

Страница 10: ...k szenl ti Stop llapotban ker l s nem ll t el semmilyen h t nem zemel sem a ventil tor sem a szivatty A vez r l sen ebben az esetben az 1 sz h l zat di da g A Start gomb lenyom s val kigyullad a 2 sz...

Страница 11: ...l tva ind tj k el a k sz l k csak 30 perc eltelt vel kezd a be ll tott rt ken zemelni Minden esetben a Stop gomb lenyom sa s a Strat gomb jb li lenyom sa ut na akkor is ha k zben a k sz l k zemel a k...

Страница 12: ...l s ind tsuk el jra Cser j k ki a ter moszt tot 7 A biztons gi t lcsordul tart ly tele van Tiszt tsuk ki 8 A biztons gi termoszt t STB nem megfelel en zemel vagy egy ltal n nem zemel Reszetelj k a ter...

Страница 13: ...att apparater SI izjavljamo da je oprema SK prehl senie e zariadenie TR hava s t c lar n n direktifler ve normlara UA YU izjavljujemo da WA 33 C AL p rshtat n direktiv t BG CZ Jsou v souladu s na zen...

Страница 14: ...nen h vitt minen auttaa est m mahdolliset vaikutukset ymp rist lle ja ihmisten terveydelle FR Se d barrasser de votre produit usag Votre produit est con u et fabriqu avec des mat riaux et des composan...

Страница 15: ...e produkt spe nia wymagania Dyrektywy Europejskiej 2002 96 EC Zaleca si zapoznanie z lokalnym systemem odbioru produkt w elektrycznych i elektronicznych Zaleca si dzia anie zgodnie z lokalnymi przepi...

Страница 16: ..._________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ ____...

Страница 17: ..._________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ ____...

Страница 18: ...023 G dki Poland office mcs ce pl MCS Central Europe Sp z o o 5A 62 023 office mcs ce pl MCS Russia LLC ul Transportnaya 22 ownership 2 142802 STUPINO Moscow region Russia info mcsrussia ru 22 2 1428...

Отзывы: