WARNING! When the acoustic pressure exceeds the value of 85 dB(A), it is necessary to 

wear personal ear protection equipment. 

Weighted root mean square acceleration according to relevant standard. : < 2.5 m/s²

 

 

4.  INSTALLATION

 

Depending on the unit being used, the petrol engine pumps from MASTER PUMPS are mounted 

on a solid base plate with vibration dampeners. These components must be in place during the 

operation of the unit since they provide for a secure standing and reduce vibrations. 

 

 

4.1.          General installation information

 

 

During the entire installation process, the unit 

must not be running.

 

 

All connection lines have to be perfectly tight since leaking lines may affect the performance of the 

pump and cause considerable damage. Therefore, please use Teflon tape to seal the contact 

surfaces between the threaded sections of the lines and the connection with the pump. This use of 

sealing material such as Teflon tape is the only way to ensure an airtight assembly. 

 

When tightening threaded connections, please do not apply excessive force which may cause 

damage.  When laying the connection pipes, you should make sure that the pump is not exposed 

to any form of weight, vibration or tension.

 

4.2.              Installation of the intake line

 

 

The inlet of the intake line is to be equipped 

with a filter for keeping away larger dirt particles

 

contained in the water which might clog or even 

damage the pump.

 

 

The liquid to be discharged enters the pump through the suction line. Please use a suction line 

having the same diameter as that of the suction port of the pump. If the suction height exceeds 4 

m, however, it is recommendable to use a 25% larger diameter 

-

 including appropriate reducer 

elements for the connectors. 

 

The inlet of the intake line is to be equipped with a filter for keeping away larger dirt particles 

contained in the water which might clog or even damage the pump. 

 

Moreover, it is highly recommended to install a check valve (non

-

return valve) which prevents the 

pressure from escaping after the pump has cut out and thus protects the pump from damage 

caused by pressure surges. This check valve may be installed either directly at the suction port of 

the pump or at the inlet of the intake line. The installation at the inlet of the intake line has proven 

to be beneficial since it facilitates the venting of this intake line by enabling it to be filled with water. 

Содержание MPG7HP24

Страница 1: ...MPG7HP24 GB ENGINE DRIVEN PUMP TRANSLATION OF THE ORIGINAL INSTRUCTIONS...

Страница 2: ...ge caused as a result of the nonobservance of instructions and provisions of the present operating instructions Any damage caused as a result of the nonobservance of the instructions and regulations c...

Страница 3: ...not smoke or work near the machine 3 Check regularly all fuel lines and tank for any leaks and cracks 4 Switch of the engine if the machine gets filled with fuel 5 Do not refuel if the machine is runn...

Страница 4: ...informed immediately at the latest within 8 days after the date of purchase SYMBOLES Compliance with appropriate safety standards Read the instruction manual before starting the engine and using your...

Страница 5: ...re portable self priming pumps operated with petrol or a petrol oil mixture depending on the model These high quality products with their convincing performance data were developed especially for main...

Страница 6: ...ine air cooled Speed 3840 min 1 Tank volume 2 0 L fuel Petrol unleaded RON 95 98 Maximum operating time 1 5h Oil capacity 400 ml Maximum flow 117 L min 7m h Max delivery height Hmax 30 m Max suction h...

Страница 7: ...ction pipes you should make sure that the pump is not exposed to any form of weight vibration or tension 4 2 Installation of the intake line The inlet of the intake line is to be equipped with a filte...

Страница 8: ...r stationary installation please fasten the pump on a suitable solid surface 5 PUTTING INTO OPERATION 5 1 Set up and visual inspection The exhaust gases of petrol engine pumps contain toxic odourless...

Страница 9: ...del being used petrol engine pumps from MASTER PUMPS are operated with petrol or a petrol oil mixture The required type of fuel is stated in the technical details of the specific model Please do not u...

Страница 10: ...o in the technical details Low oil safety feature The low oil safety feature serves to avoid damage to the engine in case there is insufficient engine oil in the crankcase Before the engine oil level...

Страница 11: ...e of water This so called dry running i e the operation of the pump without any water being discharged may cause considerable damage to the unit The petrol engine pump including the entire line system...

Страница 12: ...s of the engine too become hot during operation Therefore please avoid to touch the unit during operation and afterwards from power off to its cooling down at any points other than those intended for...

Страница 13: ...mage to the engine and downtimes Abrasive matters contained in the liquid being discharged such as sand accelerate wear and tear and reduce the performance of the pump When discharging liquids contain...

Страница 14: ...please observe all information contained in this manual regarding motor oil and oil level check 6 3 Spark plug Cleaning the spark plug and where necessary an adjustment of the electrode gaps should b...

Страница 15: ...se open the air filter box and take the filter out If necessary wash out the air filter in a non combustible solvent such as a washing up liquid dishwashing detergent For reason of the fire or explosi...

Страница 16: ...drained as well Prior to placing the unit in storage it should be cleaned thoroughly and afforded some kind of preservation should this be advisable Please make sure that the device is stored in a dry...

Страница 17: ...tape Replace intake line if it shows damage which cannot be repaired 3 Increase motor performance 4 Clean filter 5 Clean intake line 6 Remove foreign matters 7 Modify the arrangement so that the suct...

Страница 18: ...materials or manufacturing will be eliminated free of charge Any complaints are to be reported immediately upon their detection The warranty claim becomes void in the case of interventions undertaken...

Страница 19: ...you have to take or send in your defective device for repair please remove any attached parts which do not belong to the original condition of the device If any attached parts of this kind should be m...

Страница 20: ...ng system after the end of their life cycle When disposing of this product make sure that the fuel and oil are drained from the engine Should you have any questions please contact your local waste dis...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ...overeenstemming MASTER PUMPS verklaart dat de machines THERMISCHE OPPERVLAKTEPOMP MPG7HP24 in overeenstemming zijn met de volgende normen EN 809 1998 A1 2009 AfPS GS 2014 01 PAK EN 55012 2007 A1 2009...

Страница 26: ...o V Belgium in January 2019 Mr Joostens Pierre Director MASTER PUMPS rue de Goz e 81 6110 Montigny le Tilleul Belgique EG Konformit tserkl rung MASTER PUMPS erkl rt hiermit da der GASOLENE WATER PUMP...

Страница 27: ...9 Mr Joostens Pierre Direttore MASTER PUMPS rue de Goz e 81 6110 Montigny le Tilleul Belgique Declaraci n CE de conformidad MASTER PUMPS declara que las m quinas GASOLENE WATER PUMP MPG7HP24 han sido...

Страница 28: ...0032 71 29 70 86 S A V sav eco repa com Service Parts separated 32 71 29 70 83 32 71 29 70 86 Fabriqu en Chine Vervaardigd in China Made in China Hergestellt in China Fabbricato in Cina Import par Ge...

Отзывы: