6.7. Transport and storage
In order to avoid the risk of fire, allow the motor to cool down before
transporting or putting it in storage.
During transport, the water pump fuel valve should be set to OFF and the
water pump kept level, in order to avoid the fuel leaking out. Spilled petrol
or petrol vapours can ignite.
If the unit is not used over some extended period of time, the water in the pump ought to be fully
drained. Please allow the pump to dry completely in order to prevent corrosion. Likewise, the fuel
tank and the carburetor should be emptied, too. On the units with auto
-
lubrication, the motor oil
should be drained as well. Prior to placing the unit in storage, it should be cleaned thoroughly and
afforded some kind of preservation, should this be advisable.
Please make sure that the device is stored in a dry and frost
-
proof place.
If the water pump is used to pump slightly dirty water, a residue can be left in the pump. Before
storage, take in clean water with the water pump, in order to clean it.Otherwise, the pump impeller
may be damaged when it is put in service again. To clean the pump, unscrew the drain plug (2)
from the pump and drain the pump thoroughly
6.8. Troubleshooting
We decline any liability for damage caused by inappropriate repair
attempts. Any damage caused by inappropriate repair attempts will avoid
all warranty claims.
None of the remedial actions listed below must be performed with the
engine running.