Compressor Protection parameters
PAR
Description
Unit
Range
ºC
ºF
C0
Minimum time between restoring power from power cut-off compressor
Min
0 – 240
1
1
C1
Minimum time between two consecutive compressor switch-on
Min
0 – 240
2
2
C2
Minimum time between compressor switch-off and switch-on
Min
0 – 240
1
1
C3
Compressor switch on minimum time duration
Second
0 – 240
0
0
C4
Duration Comp. switch-off cabinet storage probe error“Pr1” (C5, C9)
Min
0 – 240
10
10
C5
Duration Comp. switch-on post blast chilling storage probe error“Pr1”
Min
0 – 240
10
10
C6
Condensor Temp. above which the blocked condenser alarm “COH”
°C/°F
0 – 199
80
176
C7
Condenser Temp. above which block compressor alarm “CSd”
°C/°F
0 – 199
90
194
C8
Block compressor alarm delay
Min
0 – 15
5
5
C9
Duration Comp. switch-on post deep freezing storage probe error“Pr1”
Min
0 – 240
30
30
Defrost Parameters
PAR
Description
Unit
Range
ºC
ºF
d0
Defrost interval (0 = no defrost)
Hrs
0 – 99
12
12
d1
Type of defrost:
0 = Electric defrost (fan off)
1 = Hot Gas (fan off)
2 = Air (fan on)
3 = air with door open (fan on)
…
0 – 3
2/0
2/0
d2
Defrost termination Temperature (coil) (also see d3)
°C/°F
-99 – 99
7
45
d3
Defrost Duration (0 = defrost will never activate)
Min
0 – 99
30
30
d4
Defrost Start-up of blast chilling and deep freezing cycle (1 = yes)
…
0, 1
1
1
d5
Defrosting delay on start-up
Min
0 – 99
0
0
d7
Drip time duration
Min
0 – 15
2
2
d15
Minimum duration of compressor switch-on activation of defrost
Min
0 – 99
0
0
d16
Duration of pre-dripping
Min
0 – 99
0
0
Temperature Alarm Parameters
PAR
Description
Unit
Range
ºC
ºF
A1
Cabinet temp below setpoint which the minimum temp alarm activated
°C/°F
0 – 99
10
10
A2
Enabling of minimum temperature alarm
…
0, 1
1
1
A4
Cabinet temp above setpoint which the maximum temp alarm activated
°C/°F
0 – 99
10
10
A5
Enabling of maximum temperature alarm
…
0, 1
1
1
A7
Temperature alarm DELAY
Min
0 – 240
20
20
A8
Maximum temperature alarm DELAY
Min
0 – 240
20
20
A10
Duration power cut-off alarm memorized
Min
0 – 240
5
5
AA
Duration buzzer activation on End blast chilling & deep freezing cycle
Second
0 – 240
3
3
A11
Parameter A1 & A4 differential
°C/°F
0 – 99
2
2
A13
Memorization of Temp-Control blast chilling, deep freezing un-finish
…
0, 1
1
1
A14
Reserved
…
…
…
…