Frequency range: 50Hz to 60Hz

 

Overload Protection: 

120% ranges for 60 seconds max

 

 

RESISTANCE 

Range 

Resolution 

Accuracy 

600

 

0.1

 

 
 

1.0% of rdg +3 digits

 

 
 

6k

 

1

 

60k

 

10

 

600k

 

0.1k

 

6M

 

1k

 

60M

 

10k

 

5.0% of rdg +5 digits

 

Overload Protection:   

250V dc or rms, ac for all ranges 

 
CAPACITANCE   

Range 

Resolution 

Accuracy 

600nF 

0.1nF 

 
 

4.0%of rdg +5 digits

 

6uF 

1nF 

60uF 

10nF 

600uF 

0.1uF 

1000uF 

1uF 

Overload Protection:   

250V dc or rms, ac for all ranges

 

 16 

 

FREQUENCY   

Range 

Resolution 

Accuracy 

40Hz 

1Hz 

 
 

0.1% of rdg +1digit

 

600Hz 

1Hz 

6kHz 

1Hz 

60kHz 

10Hz 

100kHz 

0.1kHz 

Measurement range:   

1V to 10V rms, 40Hz to 100kHz

 

 
ADP 

Range 

Resolution 

Accuracy 

600mV 

0.1mV 

3.0%of rdg +5 digits

 

 

AUDIBLE CONTINUITY AND DIODE 

Range 

Description 

 

If  continuity  exists  (about  less  than 
40

), built-in buzzer will sound. 

       

 

Show  the  approx,  Forward  voltage  of     
the diode. 

 

  AUTO POWER OFF     

To extend the battery life, Auto Power Off function 
is provided. If no key operations of range changing 

 17 

 

Содержание MS2026R

Страница 1: ...d hand held current clamps with double insulation overvoltage category 1000V CAT II 600V CAT III and pollution 2 This meter complies with the requirements of the following European Community Directives 89 336 EEC Electromagnetic Compatibility and 73 23 EEC Low Voltage as amended by 93 68 EEC CE Marking However electrical noise or intense electromag netic fields in the vicinity of the equipment may...

Страница 2: ...and test leads for 2 any sign of damage or abnormality before every use If any abnormal conditions exist i e broken test leads cracked cases display not reading etc do not attempt to take any measurements Do not expose the instrument to direct sunlight extreme temperature or moisture Never ground yourself when taking electrical measurements Keep your body isolated from ground by using dry clothing...

Страница 3: ...inuity Test with battery operated There is the AC measurement to be RMS or TRUE RMS about the meter It is chosen as user buy 4 Otherwise there is a radius lamp near the clamp It is lighted in measuring current PANEL DESCRIPTION 1 2 3 Transformer jaws Pick up the AC current flowing through the conductor Rotary switch Rotary switch is used to select functions HOLD button When this button is pushed t...

Страница 4: ... to manual range push this button once When the meter operates in manual ranging mode push this button to change range to the higher one and hold this button for more than 3 seconds to return to auto range mode FUNC button In range press this button to select or or function Different symbol of function will appear on the LCD button Press the button is used to turn the backlight on Press the button...

Страница 5: ... touch any electrical conductors 3 4 The polarity of the red lead connection will be indicated along with the voltage value Read the measure result from the display AC VOLTAGE MEASUREMENT 1 Insert the black and red test leads into the COM and V Hz input terminals respectively 2 Set rotary switch at desired V position Connect the test lead tips in parallel with the circuit to be measured Be careful...

Страница 6: ...range indication OL will be display 10 2 When checking in circuit resistance be sure the circuit under test has all power removed and that all capacitors have been discharged fully CONTINUITY TESTING 1 2 3 4 Insert the black and red test leads into the COM and V Hz input terminals respectively Set rotary switch at desired position Push FUNC button to select Connect the test lead tips in parallel w...

Страница 7: ...witch to Hz position Connect the test leads across the source or load under measurement The polarity of the red lead connection is positive 12 4 Read the measure result from the display NOTE 1 2 The signal amplitude must also be greater than the sensitivity level Determine that the amplitude level of the signal to be measured is not greater than the input voltage limit 250V DC AC rms ADP MEASUREME...

Страница 8: ...5mm 86mm 32mm Weight Approx 330g Operating 5 to 35 Storage temperature 10 to 50 14 DC VOLTAGE Range Resolution Accuracy 6V 1mV 0 8 of rdg 5 digits 60V 10mV 600V 0 1V 1000V 1V 1 0 of rdg 2 digits Input Impedance 10M Overload Protection 1000V DC or 700V AC RMS AC VOLTAGE Range Resolution Accuracy 6V 1mV 1 2 of rdg 5 digits 60V 10mV 600V 0 1V 700V 1V Input Impedance 10M Frequency range 40Hz to 400Hz ...

Страница 9: ...0uF 1uF Overload Protection 250V dc or rms ac for all ranges 16 FREQUENCY Range Resolution Accuracy 40Hz 1Hz 0 1 of rdg 1digit 600Hz 1Hz 6kHz 1Hz 60kHz 10Hz 100kHz 0 1kHz Measurement range 1V to 10V rms 40Hz to 100kHz ADP Range Resolution Accuracy 600mV 0 1mV 3 0 of rdg 5 digits AUDIBLE CONTINUITY AND DIODE Range Description If continuity exists about less than 40 built in buzzer will sound Show t...

Страница 10: ...Use the following procedure to replacing the battery 1 2 The Rotary Switch is used to select OFF Disconnect test leads from any live source and remove the test leads from the input terminals 18 3 4 5 Remove screws on the battery cover and open the cover Remove the exhausted battery and replace with three new 1 5V size AAA batteries Place battery cover and secure by a screw CAUTION Using this appli...

Страница 11: ...OPERATOR S INSTRUCTION MANUAL CLAMP METER HYS005013 A1 ...

Отзывы: