GENERAL
Maximum voltage:
1000V CATII 600V CATIII
Altitude:
2000m
Display:
LCD 5999 counts,
Updates 2-3/sec
Ranging method:
Auto/manual range mode
Polarity indication:
“
” display for negative
polarity
Overrange indication:
LCD will display “OL”
Low battery:
“
” will appears on LCD
Jaw capability:
40mm,Max conductor size
Power:
Battery 1.5V
3
Size AAA
Size:
225mm
×
86mm
×
32mm
Weight:
Approx. 330g
Operating:
5
℃
to
35
℃
Storage temperature:
10
℃
to 50
℃
14
DC VOLTAGE
Range
Resolution
Accuracy
6V
1mV
(
0.8%of rdg +5 digits
)
60V
10mV
600V
0.1V
1000V
1V
(
1.0%of rdg +2 digits
)
Input Impedance: 10M
Overload Protection: 1000V DC or 700V AC RMS
AC VOLTAGE
Range
Resolution
Accuracy
6V
1mV
(
1.2%of rdg +5 digits
)
60V
10mV
600V
0.1V
700V
1V
Input Impedance: 10M
Frequency range: 40Hz to 400Hz
Overload Protection: 1000V DC or 700V AC RMS
AC CURRENT
Range
Resolution
Accuracy
600A
0.1A
(
2.5%of rdg +5 digits
)
1000A
1A
(
3.0%of rdg +5 digits
)
15