Attachment 1: (CV 29) – NMRA Configuration
Bit Value
Off (0) Assignment On (Value)
Note
0
1
Driving Direction Standard
Reverse Driving Reverse
1
2
14 Speed Steps
28 Speed Steps
Automatic Recognition of 128
Speed Steps
2
4
Digital Operation Only
D Analog Operation
4
16
Internal Driving Curve
Programmable Driving Curve
CV 67-94
5
32
Short Address (CV1)
Long Address (CV17+18)
Attachment 2: (CV49) – Massoth Configuration
Bit Value
Off (0) Assingment On (Value)
Note
0
1
Parallel Data Processing Only Parallel Data Processing Automatic Detection
of Serial/Parallel
1
2
Digital Load Control Off
Digital Load Control On
2
4
Analog Load Cont. Off
Analog Load Cont. On
3
8
F1-Ouput Standard
Fast Pulse String
(P-Update) on F1
Bit3=”On” only with Bit0=”On”
Attachment 3: (CV51, 52, 54, 56, 113, 115, 117, 119) Switching Output Commands
Value
Assignment
Note
0 - 16 0=Switch Function with Light Key
1-16 = Switch Function with F-Key No. 1-16
+ 64
Switching Output “On” in Reverse only
Additional Value is to be Added
+ 128 Switching Output “On” in Standard Driving Direction only
Additional Value is to be Added