CV
Description
Default A Value
Note
1
Loco Address (standard short)
3
1.. 127 If CV29-Bit5 = 0
2
Starting Voltage
2
1.. 255 CV2 x (1/255 Track Voltage)
3
Acceleration time
3
x
1.. 255 CV3 x 2ms x (1/255 Tr. Voltage)
4
Braking time
3
x
1.. 255 CV4 x 2ms x (1/255 Tr. Voltage)
5
Top Speed
255
x
1.. 255 CV5 x (1/255 Track Voltage)
6
Mid-Speed
64
1.. 255 CV6 x (1/255 Track Voltage)
5+6 Programming in Register Mode:
Register 6 = CV- Number
Register 5 = value
---
---
CV5 and CV6 are not affected
7
Software Version
(1.2)
---
Read only
7
Decoder Reset Function
3 ranges are available
---
55
66
77
Basic CV Reset
Motor CV Reset
Light CV Reset
8
Manufacturer ID
123
---
Read only
9
Motor Frequency
0
x
0.. 3
0 = 16 kHz / 1 = 2 kHz
2 = 250 Hz / 3 = 60 Hz
13 Function Outputs in Analog Mode
(On if value set)
0
x
0.. 63
F1 = 1, F2 = 2, F3 = 4,
F4 = 8, F5 = 16, F6 = 32
17 Long Loco Address (High Byte)
18 Long Loco Address (Low Byte)
128
128 ..
10239
If CV29-Bit5 = 1
29 Configuration Table NMRA
4
x
See Attachment 1
49 Configuration Table Massoth
2
x
See Attachment 2
50 Light: Dimming Value (PWM)
32
x
1 .. 32 32 = Track Voltage
51 Front Light: Command Allocation
128
See Attachment 3
52 Rear Light: Command Allocation
64
See Attachment 3
53 F F1 + F2: Dimming Value
32
x
See Attachment 4
54 F1: Command Allocation
1
See Attachment 3
55 F1: Special Function
0
x
See Attachment 4
38