Attachment 4: (CV53, 112) – Dimming Values
Value
Assignment
Note
1 - 32 Voltage on Output
(32=full Voltage)
+ 64
F1 (F3) is dimmed only
*F1 in CV53, F3 in CV112
+ 128 F2 (F4) is dimmed only
*F2 in CV53, F4 in CV112
+ 192 Both Outputs are dimmed
*Command Allocation Value must be added to Voltage Value
Attachment 5: (CV55, 57, 114, 116, 118) – Special Functions F1 + F2 + F3 + F4 + F5
Value
Assignment
Note
0
0=Steady “On” (Standard Operation)
1..15
Blinking Steadily
(Time Base 0.25sec / value)
Symmetric Blinking
(1..15) +64
Short Term Function (Monoflop)
(Time Base 0.25sec / value)
Output is switched “off”
automatically after timeout
(1..15) + 128
(1..15) + 192
Asymmetric Blinking (Short)
Asymmetric Blinking (Long)
Output blinks 1/3 “On”
Output blinks 2/3 “On”
Attachment 5a: (CV57, 116, 118) – Expanded Special Functions F2 + F4 + F5
Value
Assignment
Note
16
nverse Coupling with Output F1 resp. F3
(Alternating Blinking)
Only in CV57 (F2 with F1) and CV116 (F4
with F3)
31
Charging Control of Voltage Buffer in Programming Mode
Only in CV118 (Buffer controlled by F5)
Attachment 6: (CV120) – Special function F6
Value
Assignment
Note
0
Steady “On” (Standard Operation)
1 .. 15 Time Base for Sound Pulse Generator
1 =slow pulse, 15=fast pulse
Attachment 7: Default CV-Settings for Reset
CV7 = 55
1=3 , 17=0 , 18=128 , 29=4 , 49=2 , 58=0 , 59=8
CV7 = 66
2=2 , 3=3 , 4=3 , 5=255 , 6=64 , 9=0 , 60=4 , 61=60 , 62=255, 64=9
CV7 = 77
13=3 , 50=32 , 51=128 , 52=64 , 53=32 , 54=1 , 55=0 , 56=2 , 57=0 , 112=32 , 113=3 , 114=0 ,
115=4 , 116=0 , 117=5 , 118=0 , 119=6 , 120=0
41