Cleaning Device PWA 1000i Page 18
7. Transport and Installation
•
The machine is delivered in carton.
•
Take the machine out of the carton and bring it to the installation site.
7.1 Requirements to the Installation Site
•
Dry and frost-free.
•
Very well ventilated, force-ventilated, both supply and exhaust.
•
Don´t position the machine close to heat sources.
•
Follow the safety instructions about the site.
•
Follow the safety instructions according to the zone designations (Page 12).
•
Maintain the ambient temperatures (5° - 35°C / 41°F - 95°F) and do not expose the machine
into direct sunlight, as this carries a risk of overheating.
•
Horizontal, conductive industrial floor (max. discharge resistance 10
8
Ohm).
7.2 Connecting Exhaust
The waste air hose must lead outdoors or to an
approved and tested extract system and the fumes
discharged safely. Make absolutely sure that the
exhaust hose is completely extended and runs at least
1m vertically so that the flow cross-section is not
restricted. Ensure that the fumes are not led into areas
where people are likely to be, into chimneys of
furnaces or fireplaces and not into exhaust ducts of
spraying and drying cabinets. Stretch the hose as far as
possible in order to avoid a reduced flow cross-section.
This is necessary in order to ensure that the exhaust
system works well.
Connect the waste air hose with the hose clamp on the
air exhaust connecting piece as shown in the adjacent
figure.
You can adjust the exhaust air flow at the throttles as needed for the length of the waste air hose.
Attention! Only use original B-TEC
waste air hoses. Risk of fire if
other hoses are used.
Waste air hose