Cleaning Device PWA 1000i Page 24
9. Care and Maintenance
9.1 Maintenance of the Machine
•
We recommend cleaning the stainless steel filter on the intake hose at regular intervals (at
least at every solvent/fluid change.) → if the filter is defective, it must be replaced
immediately. Defective filters either have heavy paint buildup, causing clogging of the filter
surface, or, the filter has a breach that allows contaminated solvent to be drawn in by the
pump, which can damage the pump or clog the washing nozzle.
•
Clean the perforated stainless steel grates and the interior walls of the machine at regular
intervals. Remove any residues from the drain pans under the grids to ensure rapid solvent
run-off.
•
It is recommended to use each function of the device shortly at least once a day in order to
avoid drying of the membranes inside the pumps and keeping the jets clean.
•
When the machines are not to be operated for a longer period of time (for example during
vacations) a clear rinse should be used after the final cleaning cycle so that the jets will not
be clogged with heavily contaminated solvent. In the unlikely event that the cleaning jets
do become blocked, then they can be easily unscrewed from the machine and cleaned
separately in neat solvent or cleaning solution and then re-fitted to the machine.
Replacement jets are available as spare parts.
•
The operating permission will expire, if other than original B-TEC spare parts are used.
Customer service: Contact your dealer, or directly:
The machine hast to be disconnected from the compressed air supply during cleaning and
maintenance!
Uwe Marx Oberflächentechnik GmbH
Friedrichsgaber Weg 390
D-22846 Norderstedt
Tel.: ++49(0)40-5281159
Fax: ++49(0)40-5231959
Email: [email protected]