8.6.3
Reduced Gigabit Media Independent Interface (RGMII)
AC Timing
8.6.3.1
RGMII AC Timing Table
Table 49: RGMII 10/100/1000 AC Timing Table at 1.8V
Table 50: RGMII 10/100 AC Timing Table at 3.3V
Description
Sym bol
Min
Max
Units Notes
Clock frequency
fCK
MHz
-
Data to Clock output skew
Tskew T
-0.50
0.50
ns
2
Data to Clock input skew
Tskew R
1.00
2.60
ns
-
Clock cycle duration
Tcyc
7.20
8.80
ns
1 , 2
Duty cycle for Gigabit
Duty_G
0.45
0.55
tCK
2
Duty cycle for 10/100 Megabit
Duty_T
0.40
0.60
tCK
2
Notes:
General comment: All values w ere measured from vddio/2 to vddio/2, unless otherw ise specified.
General comment: tCK = 1/fCK.
General comment: If the PHY does not support internal-delay mode, the PC board design requires
routing clocks so that an additional trace delay of greater than 1.5 ns and less
than 2.0 ns is added to the associated clock signal.
For 10/100 Mbps RGMII, the Max value is unspecified.
1. For RGMII at 10 Mbps and 100 Mbps, Tcyc w ill scale to 400 ns +/-40 ns and 40 ns +/-4 ns, respectively.
2. For all signals, the load is CL = 5 pF.
125.0
Description
Sym bol
Min
Max
Units Notes
Clock frequency
fCK
MHz
-
Data to Clock output skew
Tskew T
-0.50
0.50
ns
2
Data to Clock input skew
Tskew R
1.00
2.60
ns
-
Clock cycle duration
Tcyc
7.20
8.80
ns
1 , 2
Duty cycle for Gigabit
Duty_G
0.45
0.55
tCK
2
Duty cycle for 10/100 Megabit
Duty_T
0.40
0.60
tCK
2
Notes:
General comment: All values w ere measured from vddio/2 to vddio/2, unless otherw ise specified.
General comment: tCK = 1/fCK.
General comment: If the PHY does not support internal-delay mode, the PC board design requires
routing clocks so that an additional trace delay of greater than 1.5 ns
is added to the associated clock signal.
For 10/100 Mbps RGMII, the Max value is unspecified.
1. For RGMII at 10 Mbps and 100 Mbps, Tcyc w ill scale to 400 ns +/-40 ns and 40 ns +/-4 ns, respectively.
2. For all signals, the load is CL = 5 pF.