8.6.14
Transport Stream (TS) Interface AC Timing
8.6.14.1
Transport Stream Interface AC Timing Table
Table 62: Transport Stream Output Interface AC Timing Table
Table 63: Transport Stream Input Interface AC Timing Table
Description
Sym bol
Min
Max
Units
Notes
Clock frequency
fCK
MHz
1
Clock minimum low level w idth
tLOW
0.4
0.6
tCK
2
Clock minimum high level w idth
tHIGH
0.4
0.6
tCK
2
Data output valid after Clock rising edge
tOV
0.4
0.6
tCK
2, 3
Notes:
General comment: All values w ere measured from VIL(max) to VIH(min), unless otherw ise specified.
General comment: tCK = 1/fCK.
1. See "Reference Clocks" table for more details.
2. For all signals, the load is CL = 5 pF.
3. When configured to falling edge, the tOV parameter is relative to Clock falling edge.
See note 1
Description
Sym bol
Min
Max
Units
Notes
Clock frequency
fCK
MHz
1
Clock minimum low level w idth
tLOW
0.35
0.65
tCK
-
Clock minimum high level w idth
tHIGH
0.35
0.65
tCK
-
Data input setup time relative to Clock rising edge
tSU
0.30
-
tCK
2
Data input setup time relative to Clock rising edge
tHD
0.30
-
tCK
2
Notes:
General comment: All values w ere measured from VIL(max) to VIH(min), unless otherw ise specified.
General comment: tCK = 1/fCK.
1. See "Reference Clocks" table for more details.
2. When configured to falling edge, the tSU/tHD parameters are relative to Clock falling edge.
See note 1
Содержание Integrated Controller 88F6281
Страница 138: ...THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 139: ......