Electrical Specifications
AC Electrical Specifications
Copyright © 2008 Marvell
Doc. No. MV-S104859-U0 Rev. E
December 2, 2008, Preliminary
Document Classification: Proprietary Information
Page 109
8.6.11
Time Division Multiplexing (TDM) Interface AC Timing
8.6.11.1
TDM Interface AC Timing Table
Table 59: TDM Interface AC Timing Table
8.6.11.2
TDM Interface Test Circuit
Figure 31: TDM
Interface Test Circuit
Min
Max
PCLK cycle time
1/tC
0.256
8.192
MHz
1, 3
PCLK duty cycle
tDTY
0.4
0.6
tC
1
PCLK rise/fall time
tR/tF
-
3.0
ns
1, 2, 8
DTX and FSYNC valid after PCLK rising edge
tD
0.0
20.0
ns
1, 4, 6
DRX and FSYNC setup time relative to PCLK falling edge
tSU
10.0
-
ns
5, 7
DRX and FSYNC hold time relative to PCLK falling edge
tHD
10.0
-
ns
5, 7
Notes:
General comment: All values w ere measured from vddio/2 to vddio/2, unless otherw ise specified.
1. For all signals, the load is CL = 20 pF.
2. Rise and Fall times are referenced to the 20% and 80% levels of the w aveform.
3. PCLK can be configured to 0.256, 0.512, 0.768, 1.024, 1.536, 2.048, 4.096, 8.192 MHz frequencies only.
4. This parameter is relevant to FSYNC signal in master-mode only.
5. This parameter is relevant to FSYNC signal in slave-mode only.
6. In negative-mode, the DTX signal is relative to PCLK falling edge.
7. In negative-mode, the DRX signal is relative to PCLK rising edge.
8. This parameter is relevant w hen the PCLK pin is output.
Notes
8.192 MHz
Description
Sym bol
Units
CL
Test Point