38
Programming using an MP-2 Uploader
4 Select
E X T 2 0 0 v e r .
x . x
. (Note that
x . x
is the number that
corresponds to the firmware level that is loaded in the fixture. The installed
firmware version number is displayed by the LEDs on power up. The
number of red flashes in LED 1 indicates the digit to the left of the decimal
point and the number of green flashes in LED 2 indicates the digit to the
right of the decimal point. For example, if the firmware version is 1.3, LED 1
flashes red once and LED 2 flashes green three times.)
5 Select
F i x t u r e m e n u
. It is from this point you use the keys on the
uploader to navigate and select the desired menu item. For further guidance
see the following sections.
Selecting fixtures to program
Before selecting any fixture to program you must have set its control
address. If you have not yet done so, follow the instructions described in
“DMX address” on page 22.
You have the option of programing all the Exterior 200s on a data link, or an
individual Exterior 200. Fixture-specific settings such as the control address
should be made in single-fixture mode. If no other fixtures are connected,
however, then all-fixtures mode may be used. Global settings are made
easiest in all-fixtures mode. For example, it might be appropriate to program
the time, or trigger criteria into all fixtures simultaneously, while program
scenes might be programmed into fixtures individually.
Note that it is important that all the fixtures have the same software level set,
or the results will be unpredictable. For more information see, “Firmware
updates” on page 61.
Selecting a single fixture
To program a single fixture:
1 Select
S i n g l e a d d r e s s
from the Fixture menu.
2 Select a start address that corresponds to the fixture that you want to
program using the arrows.
3 Select
O K
.
Selecting all Fixtures on a data link
To program all fixtures on the data link simultaneously,
s
elect
A l l
a d d r e s s e s
from the Fixture menu.
Содержание Exterior 200
Страница 1: ...Exterior 200 user manual mar tinar chi tect ura l ...
Страница 5: ...5 SECTION 1 GETTING STARTED ...
Страница 27: ...General operation 27 SECTION 2 STAND ALONE OPERATION ...
Страница 48: ...48 Synchronous triggering during Stand Alone operation ...
Страница 49: ...Synchronous triggering during Stand Alone operation 49 SECTION 3 DMX CONTROL ...
Страница 53: ...DMX Controller operation 53 SECTION 4 OPTICS ...
Страница 57: ...Lens options 57 SECTION 5 SERVICE AND TROUBLESHOOTING ...
Страница 65: ...SECTION 6 REFERENCE ...
Страница 75: ......
Страница 76: ...www martin architectural com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 ...