GoboLED 80 D

AL2502

Manuale di istruzioni

Instructions manual

Содержание AL2502

Страница 1: ...GoboLED 80 D AL2502 Manuale di istruzioni Instructions manual ...

Страница 2: ...Gobo installation 25 4 6 Focus and zoom 27 5 0 Use of the unit 28 5 1 Setting operating mode 28 5 2 Setting DMX address 28 5 3 DMX functions 29 5 3 1 DMX functions in CH mode 1 29 5 3 2 DMX functions in CH mode 2 30 5 3 3 DMX functions in CH mode 3 30 5 3 4 DMX functions in CH mode 4 30 6 0 Master Slave and Automatic function 31 6 1 MASTER configuration 31 6 2 SLAVE configuration 32 6 3 AUTOMATIC ...

Страница 3: ...ns must be performed by a qualified staff 1 1 3 Protection against burns and fire Suitable to be installed onto normally inflammable surfaces Damaged fuses are always to be replaced with working fuses as per type and rate specified The unit is not to be installed in places where the ambient temperature exceeds 40 104 F 1 1 4 Weather protection The unit is classified as device with an IP65 weather ...

Страница 4: ... 5mm 11 216mm 8 5 150 3mm 5 9 150 3mm 5 9 64 5mm 2 5 164mm 6 5 152mm 6 273mm 10 8 425 3mm 16 7 Ø80mm 3 2 Ø10 5mm 0 4 3 0 Packaging and transport Warning Griven S r l liability will cease upon consignment of goods to the forwarder claims for damage due to trans port must be addressed directly to the forwarder Griven S r l will accept claims for broken or missing goods only within seven days of rece...

Страница 5: ...ure The unit can operate in any position Use the holes 4 Ø10 5 0 4 in the bracket to fix the unit 4 2 Adjusting light beam direction A Untighten the lateral screw 5 B Rotate the bodies of the unit towards desired direction and tighten the screw 5 4 0 Installation Ø80mm 3 2 Ø10 5mm 0 4 4 5 ...

Страница 6: ...y and connect the main cables to the pin 8 The connection of the cable to the unit must be performed re specting the label next to the terminal box Size and connection scheme of the main cable are shown in the following picture Warning Before connecting the unit verify that power supplies features are compatible with the unit features The unit must never be installed if not grounded electrically I...

Страница 7: ...rew 6 and remove the box cover B Let the signal cables pass through the cable glands 9 located onto the unit body and connect the DMX signal cables to the pin 10 The connection of the cable to the unit must be performed re specting the label next to the terminal box while from the end of the DMX controller the connection must respect the follow ing table pin 1 GND pin 2 data pin 3 data Size and co...

Страница 8: ...e A Untighten the screw 11 and remove the lower cover B Untighten the knob 12 and move sideways the lenses Warning All data wires must be isolated one from another from the shield and from the metal housing of the connectors Pin number 1 of the housing is not to be connected to the electric ground of the unit Insert a 120 Ω resistor connected to Data and Data in the last unit 6 11 12 ...

Страница 9: ...26 English C Insert the gobo in the gear 13 D Insert the rubber gobo holder 14 E Block the gobo by using the spring 15 F Close the unit again by tighten the screw 11 previously re moved 13 14 15 11 ...

Страница 10: ...11 and remove the lower cover B Move the lenses on order to adjust the beam angle and then tighten the knob 12 C Close the unit again by tighten the screw 11 previously removed Goboled 80 D produces an manually adjustable beam between 19 and 35 11 12 11 ...

Страница 11: ...sence of the signal the led will remain off When power is connected the green LED 17 will always be on The number of DMX channels used by the unit to operate will depend from the selected operating mode In case of more units operating in mode CH MODE 1 the first unit will be set with address 001 the second unit with address 004 the third unit with address 007 etc In case of more units operating in...

Страница 12: ...at the end of the reset operation the LED will light up When channel 2 is in the active range 8 248 it takes precedence over channel 1 Channel Function Value Description 1 Gobo rotation 0 15 No rotation 16 150 Proportional control 0 100 of the clockwise rotation 151 160 No rotation 161 255 Proportional control 0 100 of the counterclockwise rotation 2 Indexing 0 7 No effect 8 248 360 gobo indexing ...

Страница 13: ...51 255 Luminous output intensity 100 4 Strobo 0 5 Strobe frequency 0 6 250 Proportional control of the strobe frequency 0 100 251 255 Strobe frequency 100 Channel Function Value Description 1 Blackout Dimmer Strobo 0 15 Luminous output intensity 100 16 150 Proportional control of the luminous output intensity 100 0 151 160 Luminous output intensity 100 161 255 Proportional control of the Strobe ef...

Страница 14: ...e following table shows the output effect according to the programme MASTER SLAVE 1 SLAVE N IN OUT IN OUT SLAVE 2 IN OUT Terminal resistor 120 Ohm 6 0 Master Slave and Automatic function Unit set as Master Master ON program 1 SPEED DX right running dip switch 1 ON 1 2 3 4 5 6 7 8 9 10 11 12 1 SPEED DX 2 SPEED DX 3 SPEED DX 4 SPEED DX 1 SPEED SX 2 SPEED SX 3 SPEED SX 4 SPEED SX RANDOM Ch Mode Ch Mo...

Страница 15: ...ASTER must be followed see paragraph 8 1 MASTER configuration Adjust the dip switch Master to ON and choose the programme to be executed Dip switch Effect 1 Clockwise rotation speed 1 2 Clockwise rotation speed 2 3 Clockwise rotation speed 3 4 Clockwise rotation speed 4 5 Counterclockwise rotation speed 1 6 Counterclockwise rotation speed 2 7 Counterclockwise rotation speed 3 8 Counterclockwise ro...

Страница 16: ...t by a clean soft non scratching towel or by compressed air 8 1 2 Fans and air passages The fans and air passages must be cleaned approximately every 6 weeks the period for this periodic cleaning will depend of course upon the conditions in which the projector is operating Suitable instruments for performing this type of maintenance are a brush and a common vacuum cleaner or an air compressor 8 2 ...

Страница 17: ...he last unit of the connection Incorrect address assignment to the units Check the addresses of the units and the protocol set tings One of the unit is faulty and it is affecting the data transmission along the connection Short circuit units singularly one by one since regular working is restored The unit is set to Master or Automatic but is not running any programs In addition to setting the Mast...

Страница 18: ...tailer for information conceming the correct dis posal of their old appliance Mechanical features Height 280 5mm 11 Width 164mm 6 5 Depth 425 3mm 16 7 Weight 8 7Kg 19 2Lbs Thermal features Maximum ambient temperature 40 C 104 F Maximum surface temperature 60 C 140 F Electrical features Voltage 100 240 Vac 50 60Hz Nominal current 0 5A 230V Maximum power 100W Power factor cos φ 0 87 Thermal protecti...

Страница 19: ...a Bulgaria 16 46042 CASTEL GOFFREDO MN Italy Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it User s manual rel 1 40 ...