12
Installation
Power supply settings
Your Exterior 200 is factory-wired to one of the configurations shown in
Table 1. The factory settings are printed on the serial number label. If your
local AC voltage or frequency differ from the settings for your model, the
fixture’s power supply must be rewired by a qualified installer or technician.
Changing the power supply settings
1 Verify that the Exterior 200 is isolated from AC power. Remove the rear
cover.
2 Find the correct transformer setting for the local AC voltage in Table 2. Move
the brown transformer wire to the tap listed for the setting.
Voltage Frequency
230 V
50 Hz
245 V
50 Hz
210 V
60 Hz
Table 1: Default Power Supply Settings
Transformer:
Move brown wire to
change AC voltage setting.
Ballast:
Move black wire to change
AC frequency setting.