Service
33
P e r f o r m i n g a b o o t s e c t o r u p d a t e
1 Make sure the FiberSource CMY150 is isolated from AC power. Remove the fixture
housing.
2 Using the diagram on the inside of the fixture housing as a reference, locate the
jumper on the printed circuit board at position PL2. Move the jumper to the “BOOT”
position (across pins 1 and 2).
3 Perform a boot mode upload as described in the uploader manual.
4 When the upload is complete, disconnect the fixture from power and move the jumper
at PL2 back to the “LOCK” position (pins 2 and 3).
5 Replace the fixture housing.
F U S E R E P L A C E M E N T
Warning!
Never replace fuses with ones of a different rating!
The FiberSource CMY150 has 3 fuses. The main fuse is located on the small circuit
board and the secondary fuses for the low-voltage power supplies are located on the
main circuit board.
Fuse replacement requires a 5 mm Allen wrench.
To replace a fuse:
1 Make sure the FiberSource CMY150 is isolated from AC power.
2 Remove the fixture housing.
3 Locate the main fuse which can be found by following the power cable to the smaller
of the two printed circuit boards. This is located just to the side of the lamp housing.
The mains fuse is a T 3.15 amp, high I2t, 250 volt fuse. Replace the defective fuse
with one of the same size and rating.
4 Replace the fixture housing before applying power.