Installation
7
R e w i r i n g t h e p o w e r s u p p l y
Always use the setting that most closely matches the local AC mains voltage and
frequency.
1 Verify that the FiberSource CMY150 is isolated from AC power.
2 Remove the fixture housing using a 5mm Allen wrench.
3 On the transformer, move the brown and blue wires (those with insulated spade
plugs) to the transformer taps shown for your mains voltage (see Table 2).
Important! Do not move the grey wire from terminal 9 or the black wire from
terminal 15.
Mains voltage
Setting
Brown wire on tap
Blue wire on tap
95 - 109 V
100 V
12
10
110 - 130 V
120 V
12
9
200 - 219 V
210 V
15
10
219 - 239 V
230 V
15
9
240 - 260 V
250 V
16
9
Table 2: Transformer settings
Transformer
Ballast
10 11 12 13 14 15 16
9
2
3
4
5
6
7
8
1
orange (12 V)
orange (12 V)
grey
blue
black
brown
100 volts
10 11 12 13 14 15 16
9
2
3
4
5
6
7
8
1
orange (12 V)
orange (12 V)
grey
blue
black
brown
120 volts
purple (24 V)
purple (24 V)
purple (24 V)
purple (24 V)
Содержание 90523000