background image

  

H3C SR6600[SR6600-X] Routers 

VXLAN Command Reference 

 

 

 
 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
New H3C Technologies Co., Ltd.  
http://www.h3c.com 
 
Software version: SR6600_SR6600X-CMW710-R7740

 

Document version: 6W200-20190827

 

 

Summary of Contents for SR6600 SPE-FWM

Page 1: ...H3C SR6600 SR6600 X Routers VXLAN Command Reference New H3C Technologies Co Ltd http www h3c com Software version SR6600_SR6600X CMW710 R7740 Document version 6W200 20190827...

Page 2: ...New H3C Technologies Co Ltd any trademarks that may be mentioned in this document are the property of their respective owners Notice The information in this document is subject to change without notic...

Page 3: ...enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optional syntax choices separated by vertical bars from which you sel...

Page 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Page 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Page 6: ...el 18 tunnel global source address 19 tunnel statistics enable 19 vsi 20 vxlan 21 vxlan fast forwarding enable 21 vxlan invalid udp checksum discard 22 vxlan local mac report 23 vxlan tunnel mac learn...

Page 7: ...quests on behalf of VMs This feature snoops ARP packets to populate the ARP flood suppression table with local and remote MAC addresses If an ARP request has a matching entry the VTEP replies to the r...

Page 8: ...ion vsi name vsi name chassis chassis number slot slot number count Views Any view Predefined user roles network admin network operator mdc admin mdc operator Parameters name vsi name Specifies a VSI...

Page 9: ...minutes of the ARP flood suppression entry When the timer expires the entry is deleted Related commands arp suppression enable reset arp suppression vsi display l2vpn interface Use display l2vpn inte...

Page 10: ...ysical state of the interface Up The interface is physically up Down The interface is physically down Type L2VPN type of the interface This field displays VSI for the VXLAN feature Display detailed L2...

Page 11: ...AC entries issued through OpenFlow VXLAN does not support static local MAC entries count Displays the number of MAC address entries If you do not specify this keyword the command displays detailed inf...

Page 12: ...tor Parameters name vsi name Specifies a VSI by its name a case sensitive string of 1 to 31 characters If you do not specify a VSI this command displays information about all VSIs verbose Displays det...

Page 13: ...VSI state Up The VSI is up Down The VSI is down Administratively down The VSI has been manually shut down by using the shutdown command MTU MTU on the VSI Bandwidth Maximum bandwidth in kbps for know...

Page 14: ...ls of the VSI State Tunnel state Up The tunnel is operating correctly Blocked The tunnel is a backup proxy tunnel Its tunnel interface is up but the tunnel is blocked because the primary proxy tunnel...

Page 15: ...with the specified VXLAN Examples Display VXLAN tunnel information for all VXLANs Sysname display vxlan tunnel Total number of VXLANs 1 VXLAN ID 10 VSI name vpna Total tunnels 3 3 up 0 down 0 defect...

Page 16: ...the tunnel The flood proxy server replicates and forwards flood traffic to remote VTEPs Disabled Flood proxy is disabled Split horizon State of split horizon Enabled Split horizon is enabled on the VX...

Page 17: ...e facing interfaces use this command to disable flooding for the VSI bound to the VXLAN The VSI will not flood unknown unicast frames to VXLAN tunnel interfaces Examples Disable flooding for VSI vsi1...

Page 18: ...ange of 30 to 65535 seconds Examples Set the VXLAN statistics collection interval to 30 seconds Sysname system view Sysname l2vpn statistics interval 30 mac address static vsi Use mac address static v...

Page 19: ...been assigned the specified VXLAN tunnel The undo mac address static vsi vsi name command removes all static MAC address entries for a VSI Do not configure static remote MAC entries for tunnels that a...

Page 20: ...les Set the MTU to 1400 bytes for VSI vxlan1 Sysname system view Sysname vsi vxlan1 Sysname vsi vxlan1 mtu 1400 Related commands display l2vpn vsi reserved vxlan Use reserved vxlan to specify a reserv...

Page 21: ...specify a VSI this command clears ARP flood suppression entries on all VSIs Examples Clear ARP flood suppression entries on all VSIs Sysname reset arp suppression vsi This command will delete all entr...

Page 22: ...si name Specifies a VSI by its name a case sensitive string of 1 to 31 characters If you do not specify a VSI this command clears packet statistics on VXLAN tunnel interfaces of all VSIs Examples Clea...

Page 23: ...ive flooding mac address 000f e201 0101 Related commands flooding disable shutdown Use shutdown to shut down a VSI Use undo shutdown to bring up a VSI Syntax shutdown undo shutdown Default VSIs are no...

Page 24: ...VXLAN to provide Layer 2 connectivity for the VXLAN between two sites In unicast mode the system floods unknown unicast multicast and broadcast traffic to each tunnel in the VXLAN You can assign mult...

Page 25: ...t specify a source interface or source address for the tunnel The global source address takes effect only on VXLAN tunnels Examples Specify 1 1 1 1 as the global source address for VXLAN tunnels Sysna...

Page 26: ...VSI Syntax vsi vsi name undo vsi vsi name Default No VSIs exist Views System view Predefined user roles network admin mdc admin Parameters vsi name Specifies a VSI name a case sensitive string of 1 to...

Page 27: ...XLAN for a VSI The VXLAN ID for each VSI must be unique Examples Create VXLAN 10000 for VSI vpna and enter VXLAN view Sysname system view Sysname vsi vpna Sysname vsi vpna vxlan 10000 Sysname vsi vpna...

Page 28: ...sum discard Use vxlan invalid udp checksum discard to enable the device to drop the VXLAN packets that fail UDP checksum check Use undo vxlan invalid udp checksum discard to restore the default Syntax...

Page 29: ...information center to notify the local MAC change With the information center you can set log message filtering and output rules including output destinations For more information about configuring t...

Page 30: ...ets Views System view Predefined user roles network admin mdc admin Parameters port number Specifies a UDP port number in the range of 1 to 65535 As a best practice specify a port number in the range...

Page 31: ...t frame destined for the local site the VTEP adds 802 1Q VLAN tags to the frame before forwarding the frame In VLAN access mode VXLAN packets sent between VXLAN sites do not contain 802 1Q VLAN tags V...

Page 32: ...VXLAN IP gateways Views System view Predefined user roles network admin mdc admin Usage guidelines When local proxy ARP is enabled on distributed VXLAN IP gateways each gateway learns ARP information...

Page 33: ...an informational parameter used only by higher layer protocols for calculation You cannot adjust the actual bandwidth of an interface by using this command Examples Set the expected bandwidth to 10000...

Page 34: ...tinue Y N y description Use description to configure the description of a VSI interface Use undo description to restore the default Syntax description text undo description Default The description of...

Page 35: ...e first 27 characters of interface descriptions down Displays interfaces that are physically down as well as the down reason If you do not specify this keyword the command does not filter output by ph...

Page 36: ...ces Configuration Guide BOOTP Allocated BOOTP allocated IP address For more information see BOOTP client configuration in Layer 3 IP Services Configuration Guide PPP Negotiated IP address assigned by...

Page 37: ...e Link ADM administratively down Stby standby Protocol s spoofing Interface Link Protocol Primary IP Description Vsi100 UP UP 1 1 1 1 VSI interface100 Displays interfaces that are physically down and...

Page 38: ...rs interface vsi interface distributed gateway local Use distributed gateway local to specify a VSI interface as a distributed gateway to provide services for the local site Use undo distributed gatew...

Page 39: ...guous For example 0 255 0 255 is a valid wildcard mask ipv6 address prefix length Specifies an IPv6 subnet address and the address prefix length in the range of 1 to 128 Usage guidelines You must conf...

Page 40: ...100 Related commands interface vsi interface interface vsi interface Use interface vsi interface to create a VSI interface and enter its view or enter the view of an existing VSI interface Use undo i...

Page 41: ...mac address Default The MAC address of a VSI interface is the bridge MAC address Views VSI interface view VSI subinterface view Predefined user roles network admin mdc admin Parameters mac address Spe...

Page 42: ...erface by its number Make sure the specified VSI interface has been created on the device If you do not specify the vsi interface vsi interface id option this command clears packet statistics on all i...

Page 43: ...up group ip member local member ip undo vtep group group ip member local Default A VTEP is not assigned to any VTEP group Views System view Predefined user roles network admin mdc admin Parameters gro...

Page 44: ...fies a VTEP group by its group IP address member ip 1 8 Specifies a space separated list of up to eight member VTEP IP addresses Examples Specify VTEP group 1 1 1 1 and its member VTEPs at 2 2 2 2 3 3...

Page 45: ...arily disable remote ARP learning when the controller and VTEPs are synchronizing entries After the entry synchronization is completed use the undo vxlan tunnel arp learning disable command to enable...

Reviews: