background image

2. Put back the PCBA.

a. Place the bottle on an anti-static fixture.

b. Place the wires exiting the bottle as shown:

Battery and shoulder bolts connectors from 
the right side.

Depth/temp, LED, battery connectors and 
coax cables from the left side.

c. Apply thread locker to the threads of the PCBA screws 

and tighten using a 2 mm Allen key.

XXL bottle 

 | V1  | Replacing Parts

31

Содержание Pro Trident XXL bottle

Страница 1: ......

Страница 2: ...klist 9 Cleaning the Sensor 11 Battery Maintenance Information 12 Replacing Parts 13 Setting Up the Housing 13 Dismantling the Bottle 15 Replacing the Batteries 18 Replacing the Shoulders Bolts 19 Rep...

Страница 3: ...oftware Defined Sonar are registered trademarks of Marport All other brands products and company names mentioned are the trademark and property of its respective owners only Marport is a division of A...

Страница 4: ...of this equipment carefully read and follow the instructions in this manual Only qualified Marport dealers can do maintenance and repairs on internal components of the sensors Basic good practices Nev...

Страница 5: ...using 1 Screw maintaining the bottle inside the housing 2 End cap 3 Transducer oriented toward the vessel 4 Punches indicating the number of beams Punches in the housing show the direction and number...

Страница 6: ...ng up Trident Up Looking the face with three holes and one screw at the bottom is facing up End cap 1 Water switch 2 Negative charge 3 Positive charge 4 Shoulder bolts 5 Pressure sensor 6 Temperature...

Страница 7: ...Exploded View 1 Sensors 2 End cap 3 Batteries 4 PCBA 5 Transducer XXL bottle V1 Introduction and Presentation 7...

Страница 8: ...nectors 1 Pressure and temperature sensor 2 Shoulder bolts 3 Transducer s LED 4 7 Batteries 8 Channel C uplink 9 Channel A 10 Channel B 11 Channel D 12 Channel E XXL bottle V1 Introduction and Present...

Страница 9: ...sensor with fresh water Between uses When the sensor is not in use store in a dry area without humidity at a temperature between 10 and 70 C 14 to 158 F Not used for more than 3 months Do not leave th...

Страница 10: ...r lug to the negative lug then listen for a ping noise and check if you see the LED switched on Test the sensor measures with Mosa2 depth temperature pitch roll and if applicable spread distance echog...

Страница 11: ...driver Wash away mud or debris with warm water CAUTION Do not use highly abrasive materials or jet wash CAUTION Special care should be taken with sensors and components sensitive to mechanical shock o...

Страница 12: ...batteries at full charge or discharged for a long period of time or they will wear out Charge the battery whenever possible at any battery level Lithium ion batteries do not have a charge memory so t...

Страница 13: ...additional holes on the side with the 3 beams then place the sensor inside with the correct orientation Note The housing is delivered with 4 soft shackles dimensions 7 10x100x100 mm resistance up to...

Страница 14: ...p 3 Place the bottle inside the housing The end cap of the bottle has a screw hole on the side of the transducer that has the 3 beams It must be oriented toward the part of the housing in which you pu...

Страница 15: ...or ners 3 Install 1 screw M6 one spacer and 1 wash er on the lower part of the housing This screw must be fixed to the sensor s bottle Dismantling the Bottle Before you begin For this task you need th...

Страница 16: ...or on the ground and pull out the external tube 2 Disconnect the connectors from the PCBA a Place the bottle on an anti static fixture b Disconnect the batteries c If removing the end cap disconnect...

Страница 17: ...a 2 mm Allen key remove the retainers that are over the batteries b Pull the Velcro straps to remove the four batteries 5 Remove the end cap or transducer Repeat on the other side and other end of se...

Страница 18: ...lculation chart to measure the effective battery capacity You can also use the battery tester to fully discharge and charge the batteries then compare the measures with the characteristics on the batt...

Страница 19: ...l b Apply thread locker on the retainer screws and put them back over the batteries Replacing the Shoulders Bolts Before you begin For this task you need the following tools Philips head screwdriver T...

Страница 20: ...from the end cap a Remove the screws maintaining the 3 shoulder bolts with a Philips head screwdriver b Push the shoulder bolts out with the screwdriver c Remove o ring crushes from the holes of the...

Страница 21: ...w to 15 in lbs 2 N m Note Do not apply thread locker to the shoulder bolt screws This materi al is insulating and the shoulder bolts will overheat c Turn the end cap over and align the shoulder bolt h...

Страница 22: ...ing Screw Pressure relief spring if applicable You also need the following tools Allen keys 3 5 mm or 1 8 2 5 mm or 3 32 Flat head screwdriver size 8 to 10 Tweezers Wire stripper Crimping tool O ring...

Страница 23: ...ring 1mm thick 6 Adapter ring metal must be installed with grove side up 7 Large o ring 1 5mm thick may stay in the bottom of the hole when pressure sensor is removed 8 Pressure relief symbol look for...

Страница 24: ...nnec tor cut them at mid length and sol der the new wires to them b Clean and apply grease on all o rings c Install the components in the same order as on the picture 1 d Insert the install tool into...

Страница 25: ...owser go to Marport Authorized Service Provider MASP website https asp marport fr 2 Go to Components Add ons Pressure device and enter the pressure sensor serial number in the search box 3 From the pr...

Страница 26: ...ts displays Updated once you have saved page changes If not leave Depth options page then open it again Replacing the Temperature Sensor Before you begin For this task you need the following tools XXL...

Страница 27: ...ature sensor a Using the 22 mm wrench remove the temperature sensor and its wires b Remove the o ring seals placed at the temperature sensor location with tweezers c Fully clean the surface and hole f...

Страница 28: ...tools to do these operations on the wires another so lution is to keep the old wires connected to the connector cut them at mid length and solder the new wires to them e Install the wires into the co...

Страница 29: ...mpedance and resonance at the usual channel frequency then compare with the factory values 2 Remove the transducer and its cables See Dismantling the Bottle on page 15 3 Install the new transducer a P...

Страница 30: ...own and pass the wires through the opening in the end of the bottle b Put a new desiccant bag inside the bottle to absorb moisture c Apply Molykote grease to new o rings for the M6 screws fixing the e...

Страница 31: ...s exiting the bottle as shown Battery and shoulder bolts connectors from the right side Depth temp LED battery connectors and coax cables from the left side c Apply thread locker to the threads of the...

Страница 32: ...rs as shown b Apply silicone over the connectors onto the PCBA surface 1 Pressure Temp 2 Shoulder bolts 3 Transducer s LED 4 7 Batteries 8 Coax C Uplink 9 Coax A Down 10 Coax B Up 11 Coax D Starboard...

Страница 33: ...ring 2 Backup o ring a Inspect and clean the o ring grooves b Apply grease the 2 static o rings and 2 backup o rings c Install the o rings and make sure they are cor rectly positioned d Allow the unit...

Страница 34: ...external tube To insert the bottle back in the tube place the bottle on the ground and push the tube The side of the tube that has a small curve goes first on the side of the end cap XXL bottle V1 Rep...

Страница 35: ...rport Norge A S Breivika Industrivei 69 6018 lesund Norway supportnorge marport com SOUTH AFRICA Marport South Africa Cape Town Western Cape 11 Paarden Eiland Road Paarden Eiland 7405 csanter marport...

Страница 36: ...D Depth coefficients Downloading 21 Updating 21 E End cap 5 H Housing Description 5 Setting up 13 M Maintenance Schedule 9 P PCBA 5 Products 4 R Replacing Batteries 18 Pressure sensor 21 Shoulder bol...

Отзывы: