Allen keys: 3.5
mm and 2.5 mm
Needle
nose pliers
Silicon glue
O-ring lubricant
(Molykote 55
o-ring grease)
Procedure
1. To check if a transducer is operating correctly, use a transducer tester. Connect
each transducer coax cable to the tester and measure the impedance and
resonance at the usual channel frequency, then compare with the factory values.
2. Remove the transducer and its cables. See
Dismantling the Bottle (on page 15)
.
3. Install the new transducer.
a. Place the transducer in orientation shown. Side ele
ment
A
must be on the same side as the PCBA.
b. Put the coax cables through the opening at the end of
the bottle.
c. Put the LED wire through the small opening above the
PCBA.
XXL bottle
| V1 | Replacing Parts
29