a. Replace the o-ring seals with new lubricated seals.
b. Put the temperature sensor wires through the end cap
opening.
c. Apply thread locker to the temperature screw thread,
then tighten back into place the temperature sensor
with the wrench (torque at 60 in-lbs / 7 N-m).
d. On the new temperature sensor wires, strip the end of
each wire and crimp pins to each stripped wire.
Tip:
If you do not have the necessary tools to
do these operations on the wires, another so
lution is to keep the old wires connected to
the connector, cut them at mid-length and
solder the new wires to them.
e. Install the wires into the connector, as shown on the
picture.
3. Check that the hardware operates correctly:
◦
Test the sensor measures on a broad temperature range.
◦
You can for example measure the surface temperature of the sensor with an
infrared thermometer and compare with the measure displayed on Mosa2
or Scala2.
Replacing the Transducer
Before you begin
For this task you need the following tools:
XXL bottle
| V1 | Replacing Parts
28
Содержание Pro Trident XXL bottle