Copyright by Servizio Clienti ANGELO PO Spa
96
5.4.3.
Gas Valve Adjustment
Loosen the protective brass cap and prepare a 4mm Allen wrench to set the gas values.
If the combustion values at minimum do not correspond to the
recommended ones, intervene on the valve offset adjustment.
Now, if the CO2 is lower than the recommended value, slowly
screw clockwise (see figure at the side) to enrich the mixture.
If the CO2 is higher, slowly unscrew to make the mixture
lighter.
The adjustment is very sensitive and small movements are
recommended (a quarter of a turn varies the CO2 by about
1%) and wait for the fume analyzer to detect the variation and
stabilize.
Once the adjustment has been made, repeat the test
procedure.
At the end of the adjustment, refit the protective cap of the adjustment screw.
Attention: the adjustment of the PR.ADJ screw does not affect the increase of the
oven power.
Содержание ANGELO PO ACT.O
Страница 1: ...Copyright by Servizio Clienti ANGELO PO Spa Rev 0...
Страница 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 1 3 2 Gas Oven connection diagram...
Страница 51: ...Copyright by Servizio Clienti ANGELO PO Spa 51...
Страница 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67...
Страница 72: ...Copyright by Servizio Clienti ANGELO PO Spa 72...
Страница 88: ...Copyright by Servizio Clienti ANGELO PO Spa 88 5 2 9 Heat exchanger...
Страница 98: ...Copyright by Servizio Clienti ANGELO PO Spa 98 POSITION OF MAGNET DURING THE COMBUSTION FUMES WITHDRAWAL...
Страница 110: ...Copyright by Servizio Clienti ANGELO PO Spa 110...
Страница 115: ...Copyright by Servizio Clienti ANGELO PO Spa 115...
Страница 126: ...Copyright by Servizio Clienti ANGELO PO Spa 126 6 4 Operation of the washing system components...
Страница 127: ...Copyright by Servizio Clienti ANGELO PO Spa 127 ALARM LOGIC E34...
Страница 130: ...Copyright by Servizio Clienti ANGELO PO Spa 130 2 Closing of the drain valve 3 Washing tank filling collection tank...
Страница 131: ...Copyright by Servizio Clienti ANGELO PO Spa 131 4 Washing pump operation 5 Opening of the drain valve...
Страница 149: ...Copyright by Servizio Clienti ANGELO PO Spa 149 AT 122 oven...
Страница 150: ...Copyright by Servizio Clienti ANGELO PO Spa 150 AT 201 202 ovens...
Страница 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 7 5 3 General scheme of the cooling fans ALL ALL 122 201 202 201 202 202...
Страница 160: ...Copyright by Servizio Clienti ANGELO PO Spa 160 photo 3 photo 4...
Страница 175: ...Copyright by Servizio Clienti ANGELO PO Spa 175...
Страница 184: ...Copyright by Servizio Clienti ANGELO PO Spa 184...