179
9. ALARMS
ALARM
Display
NOTES
SERVICE
Steam H2O flow
(too low)
H2O
Block steam operation
- insufficient H2O connection pressure
-
faulty “chamber H2O” flow meter
-
faulty “chamber H2O” input on Power Board
- faulty H2O solenoid valve
-
faulty “chamber H2O” solenoid valve output on
Power Board
-
incorrect “chamber H2O” circuit electric
connections
- Check the water solenoid valve
operation
- Check the F4 3.15A T fuse on the
power board
- Check 230VAC voltage on pole 9
of the power board (SV power
supply)
- Check the filter on the water inlet.
- Check the mains pressure
- Check the flow meter operation
(with the service menu procedure)
- Check 12Vdc (direct) voltage
between pin 63 and 64 on the
power board (flow meter power
supply)
- Check that the calibrated nozzle
is not clogged (remove the hose
connector)
Drain H2O flow
(too low)
H2O.
Signal only
- insufficient H2O connection pressure
- faulty drain H2O faulty flow meter
-
faulty “drain H2O” input on Power Board
-
faulty “drain H2O” solenoid valve
-
faulty “drain H2O” solenoid valve output on
Power Board
-
incorrect “drain H2O” circuit electric
connections
- Check the water solenoid valve
operation
- Check the F4 3.15A T fuse on the
power board
- Check 230VAC voltage on pole
10 of the power board (SV power
supply)
- Check the filter on the water inlet.
- Check the mains pressure
- Check the flow meter operation
(with the test procedure in the
service menu)
- Check 12Vdc (direct) voltage
between pin 66 and 67 on the
power board (flow meter power
supply)
- Check that the calibrated nozzle
is not clogged (remove the hose
connector)
H2O flow (too low)
to the chamber
during washing
H2OL
See paragraph 6.6
H2O flow (too low)
to the drain during
washing
H2O.L
See paragraph 6.6
Door switch
OPE
STOP cooking (and washing)
- too many consecutive start without opening
the door (20 times)
- faulty door micro switch
- Faulty Power Board
- Check the oven door micro-
switch, wired on pin 60 and 61 of
the power board. It may be faulty
or short-circuited
Содержание ANGELO PO ACT.O
Страница 1: ...Copyright by Servizio Clienti ANGELO PO Spa Rev 0...
Страница 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 1 3 2 Gas Oven connection diagram...
Страница 51: ...Copyright by Servizio Clienti ANGELO PO Spa 51...
Страница 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67...
Страница 72: ...Copyright by Servizio Clienti ANGELO PO Spa 72...
Страница 88: ...Copyright by Servizio Clienti ANGELO PO Spa 88 5 2 9 Heat exchanger...
Страница 98: ...Copyright by Servizio Clienti ANGELO PO Spa 98 POSITION OF MAGNET DURING THE COMBUSTION FUMES WITHDRAWAL...
Страница 110: ...Copyright by Servizio Clienti ANGELO PO Spa 110...
Страница 115: ...Copyright by Servizio Clienti ANGELO PO Spa 115...
Страница 126: ...Copyright by Servizio Clienti ANGELO PO Spa 126 6 4 Operation of the washing system components...
Страница 127: ...Copyright by Servizio Clienti ANGELO PO Spa 127 ALARM LOGIC E34...
Страница 130: ...Copyright by Servizio Clienti ANGELO PO Spa 130 2 Closing of the drain valve 3 Washing tank filling collection tank...
Страница 131: ...Copyright by Servizio Clienti ANGELO PO Spa 131 4 Washing pump operation 5 Opening of the drain valve...
Страница 149: ...Copyright by Servizio Clienti ANGELO PO Spa 149 AT 122 oven...
Страница 150: ...Copyright by Servizio Clienti ANGELO PO Spa 150 AT 201 202 ovens...
Страница 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 7 5 3 General scheme of the cooling fans ALL ALL 122 201 202 201 202 202...
Страница 160: ...Copyright by Servizio Clienti ANGELO PO Spa 160 photo 3 photo 4...
Страница 175: ...Copyright by Servizio Clienti ANGELO PO Spa 175...
Страница 184: ...Copyright by Servizio Clienti ANGELO PO Spa 184...