Copyright by Servizio Clienti ANGELO PO Spa
108
5.5.
Problems during the testing procedure
At minimum it turns off
1. Increase the valve adjustment (PR.ADJ) until the oven
remains on at minimum.
2. Check the type of gas and the pressure.
3. Check gas nozzle.
4. Check the gas pipe fixing.
5. Check the flame detector wiring.
6. Check the pipe of benchmark pressure test point is clear.
7. Check that the blower fan air intake is clean.
8. Check the electrical connection.
At maximum the flame
tends
to
go
out
or
“detach” from the burner.
1. Check gas nozzle.
2. Check the type of gas and the inlet pressure.
3.
Measure the CO and CO2 values and compare them with
the min/max values.
ALARM E27:
Gas testing failed
Check that 200°C have not been exceeded in the chamber, if so
perform a cooldown and then perform the test again. Check that
the 10 minutes available for each test phase have not expired, if so
perform the test again without letting this time expire.
If other alarms appear, see the “GAS ALARMS TABLE”
Important: at the end of each intervention on the gas system, perform the gas
test procedure measuring the CO and CO2 and checking that the values fall
within the ranges declared by the manufacturer
Содержание ANGELO PO ACT.O
Страница 1: ...Copyright by Servizio Clienti ANGELO PO Spa Rev 0...
Страница 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 1 3 2 Gas Oven connection diagram...
Страница 51: ...Copyright by Servizio Clienti ANGELO PO Spa 51...
Страница 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67...
Страница 72: ...Copyright by Servizio Clienti ANGELO PO Spa 72...
Страница 88: ...Copyright by Servizio Clienti ANGELO PO Spa 88 5 2 9 Heat exchanger...
Страница 98: ...Copyright by Servizio Clienti ANGELO PO Spa 98 POSITION OF MAGNET DURING THE COMBUSTION FUMES WITHDRAWAL...
Страница 110: ...Copyright by Servizio Clienti ANGELO PO Spa 110...
Страница 115: ...Copyright by Servizio Clienti ANGELO PO Spa 115...
Страница 126: ...Copyright by Servizio Clienti ANGELO PO Spa 126 6 4 Operation of the washing system components...
Страница 127: ...Copyright by Servizio Clienti ANGELO PO Spa 127 ALARM LOGIC E34...
Страница 130: ...Copyright by Servizio Clienti ANGELO PO Spa 130 2 Closing of the drain valve 3 Washing tank filling collection tank...
Страница 131: ...Copyright by Servizio Clienti ANGELO PO Spa 131 4 Washing pump operation 5 Opening of the drain valve...
Страница 149: ...Copyright by Servizio Clienti ANGELO PO Spa 149 AT 122 oven...
Страница 150: ...Copyright by Servizio Clienti ANGELO PO Spa 150 AT 201 202 ovens...
Страница 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 7 5 3 General scheme of the cooling fans ALL ALL 122 201 202 201 202 202...
Страница 160: ...Copyright by Servizio Clienti ANGELO PO Spa 160 photo 3 photo 4...
Страница 175: ...Copyright by Servizio Clienti ANGELO PO Spa 175...
Страница 184: ...Copyright by Servizio Clienti ANGELO PO Spa 184...