Copyright by Servizio Clienti ANGELO PO Spa
17
2.3.
Gas Oven Installation
- Check adequate cable capacity and presence of adequate protections
- Check the correct power supply voltage and the correct electrical connection (see
“Gas Oven connection diagram”)
Model
Max power
Min power
Voltage
Frequency
AT61G / GW
14
7
230V 1N ~
50Hz
AT101G / GW
20
7,4
230V 1N ~
50Hz
AT201G
40
14,5
230V 1N ~
50Hz
AT82G
27
16,5
230V 1N ~
50Hz
AT122G
32
9,5
230V 1N ~
50Hz
AT202G
55
34
230V 1N ~
50Hz
- All ovens are supplied and tested ONLY for G20 gas (the other nozzles for gas
transformation are supplied)
- Check the type of gas supplied
- If the gas supplied is different from G20 (Natural Gas) it is necessary to change the
gas nozzle and insert the one corresponding to the gas type.
- Check the dynamic supply pressure of the GAS
GAS type
Pnom (mbar)
Pmin (mbar)
Pmax (mbar)
G20
20
17
25
G25
25
20
30
G30
28-30
25
35
G31
37
25
45
- During installation, the connection between
PHASE
and
NEUTRAL
must be
respected, i.e. the polarities must not be reversed. Incorrect connection causes a
lower reading of the ion signal detected by the spark igniter in microampere (µA).
- Proceed with the fumes analysis.
Содержание ANGELO PO ACT.O
Страница 1: ...Copyright by Servizio Clienti ANGELO PO Spa Rev 0...
Страница 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 1 3 2 Gas Oven connection diagram...
Страница 51: ...Copyright by Servizio Clienti ANGELO PO Spa 51...
Страница 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67...
Страница 72: ...Copyright by Servizio Clienti ANGELO PO Spa 72...
Страница 88: ...Copyright by Servizio Clienti ANGELO PO Spa 88 5 2 9 Heat exchanger...
Страница 98: ...Copyright by Servizio Clienti ANGELO PO Spa 98 POSITION OF MAGNET DURING THE COMBUSTION FUMES WITHDRAWAL...
Страница 110: ...Copyright by Servizio Clienti ANGELO PO Spa 110...
Страница 115: ...Copyright by Servizio Clienti ANGELO PO Spa 115...
Страница 126: ...Copyright by Servizio Clienti ANGELO PO Spa 126 6 4 Operation of the washing system components...
Страница 127: ...Copyright by Servizio Clienti ANGELO PO Spa 127 ALARM LOGIC E34...
Страница 130: ...Copyright by Servizio Clienti ANGELO PO Spa 130 2 Closing of the drain valve 3 Washing tank filling collection tank...
Страница 131: ...Copyright by Servizio Clienti ANGELO PO Spa 131 4 Washing pump operation 5 Opening of the drain valve...
Страница 149: ...Copyright by Servizio Clienti ANGELO PO Spa 149 AT 122 oven...
Страница 150: ...Copyright by Servizio Clienti ANGELO PO Spa 150 AT 201 202 ovens...
Страница 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 7 5 3 General scheme of the cooling fans ALL ALL 122 201 202 201 202 202...
Страница 160: ...Copyright by Servizio Clienti ANGELO PO Spa 160 photo 3 photo 4...
Страница 175: ...Copyright by Servizio Clienti ANGELO PO Spa 175...
Страница 184: ...Copyright by Servizio Clienti ANGELO PO Spa 184...