Copyright by Servizio Clienti ANGELO PO Spa
50
Cycle Test 3
REL 15/ID3
Drain Valve Fat to check CLOSE
In 58
Cycle Test 4
REL 2/CNT1
Steam Generation valve for 10 seconds to
check flow counter
Cycle Test 5
REL 3/CNT2
Drain Water valve for 10 seconds to check
flow counter
In the I/O screen are visible the measured value of the
multipoint temperature probe
in
Celsius degree,
ID5
displays the door’s switch (OFF= door closed, ON= door open) and
IDT4
displays the safety stat condition (OFF= standard operation, ON= tripped).
*
REL6
:
1 means BOTTOM (only for models 201/202)
ELECTR.: Cooling fan(s) - Inverter (K4)
– Safety contactor heating element (K1)
201/202 ELECTR.: Cooling fan(s) - Inverter 1 (K8)
– Safety contactors heating element
(Bottom K1 & Top K4)
GAS: Cooling fan(s) - Inverter (K1) - Combustion board
201/202 GAS: Cooling fan(s) - Inverter 1 (K2) - Combustion board 1
*
REL7
:
2 means TOP
201/202 ELECT.: Inverter 2 (K7)
201/202 GAS: Inverter 2 (K1) - Combustion board 2
*
REL8
:
Wired only on ELECTRIC models - resets after 1 second
*
REL9
:
Wired only on ELECTRIC models - resets after 1 second
Содержание ANGELO PO ACT.O
Страница 1: ...Copyright by Servizio Clienti ANGELO PO Spa Rev 0...
Страница 8: ...Copyright by Servizio Clienti ANGELO PO Spa 8 1 3 2 Gas Oven connection diagram...
Страница 51: ...Copyright by Servizio Clienti ANGELO PO Spa 51...
Страница 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67...
Страница 72: ...Copyright by Servizio Clienti ANGELO PO Spa 72...
Страница 88: ...Copyright by Servizio Clienti ANGELO PO Spa 88 5 2 9 Heat exchanger...
Страница 98: ...Copyright by Servizio Clienti ANGELO PO Spa 98 POSITION OF MAGNET DURING THE COMBUSTION FUMES WITHDRAWAL...
Страница 110: ...Copyright by Servizio Clienti ANGELO PO Spa 110...
Страница 115: ...Copyright by Servizio Clienti ANGELO PO Spa 115...
Страница 126: ...Copyright by Servizio Clienti ANGELO PO Spa 126 6 4 Operation of the washing system components...
Страница 127: ...Copyright by Servizio Clienti ANGELO PO Spa 127 ALARM LOGIC E34...
Страница 130: ...Copyright by Servizio Clienti ANGELO PO Spa 130 2 Closing of the drain valve 3 Washing tank filling collection tank...
Страница 131: ...Copyright by Servizio Clienti ANGELO PO Spa 131 4 Washing pump operation 5 Opening of the drain valve...
Страница 149: ...Copyright by Servizio Clienti ANGELO PO Spa 149 AT 122 oven...
Страница 150: ...Copyright by Servizio Clienti ANGELO PO Spa 150 AT 201 202 ovens...
Страница 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 7 5 3 General scheme of the cooling fans ALL ALL 122 201 202 201 202 202...
Страница 160: ...Copyright by Servizio Clienti ANGELO PO Spa 160 photo 3 photo 4...
Страница 175: ...Copyright by Servizio Clienti ANGELO PO Spa 175...
Страница 184: ...Copyright by Servizio Clienti ANGELO PO Spa 184...