background image

INSTALLATION OF HEATER

ASSEMBLY INTO BACK BOX

1. Re-install fan deck using two screws.

2. Connect field supply wiring to heater pigtail leads (See figure 4).

Connect field ground wire to green ground lead wire.

3. Install front cover. Push on thermostat knob.

CHECK OPERATION AND SET THERMOSTAT

1. Switch on power supply to heater.

2. Rotate thermostat knob fully clockwise. Heating element and fan should

come on, causing warm air to flow from discharge grille.

3. Allow heater to operate until room is comfortable, then rotate thermo-

stat counter-clockwise until thermostat clicks. The unit will continue to

cycle on and off to maintain temperature.

4. Increase or decrease the setting as required until the desired room tem-

perature is maintained.

For best results, the heater should be left “ON” constantly during the

heating season as the thermostat, when properly set, will maintain the

desired room temperature. In the counter-clockwise position, the heater

will remain off. This unit was shipped with a plug button to render the

thermostat tamper resistant. Remove the thermostat knob and insert

plug button in clearance hole guide.

For ceiling mounted units, a remote wall mounted line voltage thermostat

may be installed to control the unit. Follow instructions for the wall ther-

mostat. Turn the thermostat knob on the unit to full clockwise position for

maximum heat, remove the knob and insert plug button in clearance hole

guide. Set your wall thermostat to desired set point.

OPERATION NOTICE

Your heater is equipped with an automatic reset limit control that will

automatically turn the heater OFF to prevent a fire if the heater

overheats. Should this occur, the indicator light will illuminate and will

continue to shine until the limit resets.

SPECIFICATIONS

MODEL

WIRE

NO.

VOLTS

AMPS

WATTS BTU/HR

SIZE

D1012C

120

8.3

1000

3413

14 awg

D1512

120

12.6

1500

5120

12 awg

208

3.6

750

2560

14 awg

D1024C

240

4.2

1000

3413

14 awg

D2024

208

7.2

1500

5120

14 awg

240

8.3

2000

6826

14 awg

To insure proper grounding of heater and prevent a possible electric

shock, the field supply ground wire must be attached to heater green

ground lead wire.

CAUTION

!

To prevent possible wiring damage, cut excess supply wires inside

backbox to provide approximately 6” (152 mm) for connection to

heater leads. After connections are made, make sure connections

are tight and all wiring is positioned away from fan blade and heating

element.

CAUTION

!

THE ILLUMINATED INDICATOR LIGHT SIGNIFIES THE HEATER HAS

BEEN SUBJECTED TO SOME ABNORMAL CONDITION CAUSING IT

TO OVERHEAT. CHECK HEATER TO INSURE THAT IT HAS NOT BEEN

BLOCKED IN ANY MANNER (IF SO, REMOVE BLOCKAGE). IF THERE

IS NO INDICATION OF BLOCKAGE, IT IS RECOMMENDED THAT

HEATER BE CHECKED BY A REPUTABLE ELECTRICIAN OR REPAIR

SERVICE TO INSURE THE HEATER HAS NOT BEEN DAMAGED.

CAUTION

!

IMPORTANT INFORMATION

MODEL

WATTS

AMPS

DATE

VOLTS

PH

Hz

D2024

MM-YY

240/208

1

60

2000/1500

8.3/7.2

Bennettsville, SC 29512 USA

3

Содержание D Series

Страница 1: ... accordance with National and Local Electrical Codes and the heater must be grounded 3 Verify the power supply voltage coming to heater matches the ratings printed on the heater nameplate before energizing 4 This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces 5 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an ...

Страница 2: ...rection Heaters are also approved for surface mounting on walls or ceilings Refer to instructions for installation of the DSMK Surface Mounting Frame INSTALLATION OF BACK BOX IN NEW CONSTRUCTION NOTE A If the finished wall is already up follow instructions for INSTAL LATION OF BACK BOX IN EXISTING CONSTRUCTION 1 Determine which side of the back box is to be mounted against a stud or ceiling joist ...

Страница 3: ...the knob and insert plug button in clearance hole guide Set your wall thermostat to desired set point OPERATION NOTICE Your heater is equipped with an automatic reset limit control that will automatically turn the heater OFF to prevent a fire if the heater overheats Should this occur the indicator light will illuminate and will continue to shine until the limit resets SPECIFICATIONS MODEL WIRE NO ...

Страница 4: ...WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETHER BASED UPON NEGLIGENCE TORT STRICT LIA BILITY OR CONTRACT Some states do not allow the exclusion or limitation of ...

Страница 5: ... Códigos Eléctricos y Nacionales y el calentador debe estar conectado a tierra 3 Antes de activar verificar que el voltaje de la electricidad de alimentación corresponda con las clasificaciones nominales impresas en la placa de especificaciones del calentador 4 Este calentador está caliente al usar Para evitar quemaduras no permitir que la piel expuesta toque las superficies calientes 5 No inserta...

Страница 6: ...uc ciones de INSTALACION DE LA CAJA POSTERIOR EN CONSTRUCION EXISTENTE 1 Determinar cuál lado de la caja posterior se va a montar contra un mon tante de pared o vigueta de cieloraso ver la Figura 2 Al instalar la caja posterior permitir espacio para el espesor de la pared terminada El borde de la caja posterior debe instalarse al ras con la superficie terminada Se proporcionan marcas en el lado de...

Страница 7: ...a el termostato de pared Para obtener un efecto térmico máximo girar completamente la perilla del termostato en el sentido de las agujas del reloj extraer la perilla e insertar el botón de tapón en la guía de separación del orificio Graduar el termostato de pared al punto deseado de control AVISO DE OPERACION Su calentador está equipado con un control automático de regraduación que lo apaga automá...

Страница 8: ...LIZACION Y APTITUD PARA UN PROPOSITO PARTICULAR QUE EXCEDAN LAS GARANTIAS EXPRESAS MENCIONADAS PREVIAMENTE SON RECHAZADAS Y EXCLUIDAS DEL PRESENTE ACUERDO MARLEY ENGINEERED PRODUCTS NO SERA RESPONSABLE POR PERJUICIOS CONSECUENTES ORIGI NADOS CON RESPECTO AL PRODUCTO YA SEA BASADO EN NEGLIGENCIA LEY RESPONSABILIDAD ESTRICTA O CONTRATO Algunos Estados no permiten la exclusión o limitación de perjuic...

Страница 9: ...avec les règlements nationaux et locaux et reliez le radiateur à la terre 3 Vérifiez que la tension d alimentation secteur arrivant au radiateur corre spond à la prescription sur sa plaque d identification avant de l alimenter 4 Le radiateur est chaud en fonctionnement Pour ne pas vous brûler ne lais sez pas la peau nue toucher ses surfaces chaudes 5 N insérez pas et ne laissez pas pénétrer d obje...

Страница 10: ... du caisson arrière sera monté contre le poteau de cloison ou la solive de plafond voir Schéma 2 Laissez la place pour l épaisseur du revêtement de surface en mettant le caisson en place Le dessus du caisson doit affleurer le niveau qu aura le revêtement posé Des repères sur le caisson indiquent des épais seurs de revêtement de 12 7 mm 1 2 et 15 9 mm 5 8 2 Démontez la plate forme de ventilateur du...

Страница 11: ...al Tournez le thermostat d origine du radiateur en position ouverte à fond pour un réglage de chaleur maximale enlevez son bouton et mettez le bouchon dans le guidage de trou de dégagement Réglez votre thermostat mural au point de consigne voulu REMARQUE SUR LE FONCTIONNEMENT Votre radiateur est muni d une coupure automatique sur contrôle de limite qui va arrêter automatiquement l élément chauffan...

Страница 12: ...LAIREMENT EXPRIMÉE OU SOUS ENTENDUE ET TOUTE GARANTIE SOUS ENTENDUE AYANT TRAIT À LʼAPPLICATION DU PRODUIT À UNE UTILISATION AUTRE QUE CELLE INDIQUÉE DANS LA GARANTIE QUI PRÉCÈDE EST SANS VALEUR ET NʼEST PAS VISÉE PAR LA PRÉSENTE ENTENTE MARLEY ENGINEERED PRODUCTS NʼEST PAS RESPONSABLE DES DOMMAGES AU PRODUIT RÉSULTANTS DʼUNE NÉGLIGENCE DʼUN TORT DʼUNE RESPONSABILITÉ STRICTE OU DU CONTRAT Certaine...

Отзывы: